Difference between revisions of "Infiltration trenches"

From LID SWM Planning and Design Guide
Jump to navigation Jump to search
 
(13 intermediate revisions by 3 users not shown)
Line 1: Line 1:
<imagemap>
File:Kortright trench update.png|thumb|600 px|This infiltration trench features an inlet composed of [[geotextile| filter fabric]] and decorative [[stone| river stone]], which provides some [[pretreatment]] and can easily be removed and replaced as part of routine sediment removal maintenance. For more details click [https://sustainabletechnologies.ca/app/uploads/2016/08/BioVSTrench_TechBrief__July2015.pdf here.] <span style="color:red">''A note: The following is an "image map", feel free to explore the image with your cursor and click on highlighted labels that appear to take you to corresponding pages on the Wiki.''</span>
rect 1061 1333 1388 1631 [[Curb cuts|Concrete Curb]]
rect 2211 1339 2527 1640 [[Curb cuts|Concrete Curb]]
rect 1400 1366 2182 1634 [[Stone|River Rock]]   
rect 1595 1091 1946 1186 [[Geotextiles|Geotextile OPSS 1860 Approved Fabric]] 
rect 1344 847 2144 962 [[Permeable pavements|Permeable Paver]] 
rect 2536 1336 3330 1381 [[Permeable pavements|Permeable Paver]]
rect 1185 1041 2017 971 [[Choker layer|High performance bedding]]
rect 1075 1637 1394 1788 [[OPSS aggregates|Crushed Limestone]]
rect 2206 1708 3336 1944 [[OPSS aggregates|Crushed Limestone]]
rect 2214 1640 2524 1711 [[OPSS aggregates|Crushed Limestone]]
rect 2533 1384 3330 1440 [[Choker layer|High performance bedding]]
rect 2542 1443 3330 1702 [[OPSS aggregates|Well-graded granular A Material (OPSS 1010)]]
circle 2858 2125 69 [[Underdrains|Underdrain]]
rect 1403 1968 2182 1649 [[Reservoir aggregate|Clearstone]]
rect 1394 1971 3333 2286 [[Reservoir aggregate|Clearstone]]
rect 1 1339 1061 2470 [[Soil groups|Native Soil]]
     
</imagemap>
This article is about underground systems which distribute concentrated flow along a level, linear facility to promote infiltration to native soils. <br>
This article is about underground systems which distribute concentrated flow along a level, linear facility to promote infiltration to native soils. <br>
See [[exfiltration trenches]] for guidance on infiltration trench systems integrated with conventional storm sewers and manholes that provide both infiltration and conveyance functions.  
See [[exfiltration trenches]] for guidance on infiltration trench systems integrated with conventional storm sewers and manholes that provide both infiltration and conveyance functions.  


[[File:Kortright trench.PNG|thumb|This infiltration trench features an inlet composed of [[geotextile| filter fabric]] and decorative [[stone| river stone]], which provides some [[pretreatment]] and can easily be removed and replaced as part of routine sediment removal maintenance. For more details click [https://sustainabletechnologies.ca/app/uploads/2016/08/BioVSTrench_TechBrief__July2015.pdf here] ]] 
{{TOClimit|2}}
{{TOClimit|2}}
==Overview==
==Overview==
{{float right|{{#widget:YouTube|id=DLXsb1FwKD4}}}}
[[File:Infiltration Trench.png|450px|thumb|Images and schematic depicting residential infiltration trenches, commonly referred to as [[soakaways]], that when installed help reduce the risk of flooding and limit negative impacts to stormwater quality.<ref>The City of Windsor. Stormwater Solutions: Infiltration Trenches. https://www.citywindsor.ca/residents/environment/climate-change-adaptation/climate-resilient-home/Documents/Infiltration%20Trench.pdf. Updated 2021. Accessed 30 August, 2021</ref>]]
Infiltration trenches are underground, linear, rectangular or trapezoidal excavations with level or gently sloping bottom grade, geotextile filter fabric on sidewalls and top and filled with clean, crushed angular stone or other void-forming structures. They are well suited to sites where available space for infiltration is limited to strips of land between buildings or properties, or along road rights-of-way. They can also be referred to as infiltration galleries.  See [[Perforated Pipe Systems]] fact sheet for guidance on infiltration trench systems integrated with conventional storm sewers that provide both infiltration and conveyance functions.
Infiltration trenches are underground, linear, rectangular or trapezoidal excavations with level or gently sloping bottom grade, geotextile filter fabric on sidewalls and top and filled with clean, crushed angular stone or other void-forming structures. They are well suited to sites where available space for infiltration is limited to strips of land between buildings or properties, or along road rights-of-way. They can also be referred to as infiltration galleries.  See [[Perforated Pipe Systems]] fact sheet for guidance on infiltration trench systems integrated with conventional storm sewers that provide both infiltration and conveyance functions.
{{textbox|1=Infiltration trenches are an ideal technology for:  
{{textbox|1=Infiltration trenches are an ideal technology for:  
*Installing below any type of surface or landscape
*Installing below any type of surface or landscape
*Balancing the requirements to infiltrate excess stormwater whilst conveying excess}}
*Balancing the requirements to infiltrate excess stormwater whilst conveying excess}}
Take a look at the downloadable Soakaways, Infiltration Trenches & Chambers Factsheet below for a .pdf overview of this LID Best Management Practice:
{{Clickable button|[[File:Soakaways infiltration et.al.png|250 px|link=https://wiki.sustainabletechnologies.ca/images/b/b1/Infiltration_trenches_et_al_final.pdf]]}}
'''The fundamental components of an infiltration trench are:'''  
'''The fundamental components of an infiltration trench are:'''  
*Water storage reservoir, filled with [[Reservoir_gravel|coarse aggregate]], possibly void-forming structures to minimize depth and conserve aggregate, and organic material derived from untreated wood (aids in dissolved nitrogen removal);
*Water storage reservoir, filled with [[Reservoir_gravel|coarse aggregate]], possibly void-forming structures to minimize depth and conserve aggregate, and organic material derived from untreated wood (aids in dissolved nitrogen removal);
Line 35: Line 64:


===Water Table===
===Water Table===
Maintaining a separation of one (1) metre between the elevations of the base of the practice and the seasonally high water table, or top of bedrock is recommended. Lesser or greater values may be considered based on groundwater mounding analysis. See STEP LID Planning and Design Guide wiki page, [[Groundwater]] for further guidance and spreadsheet tool.
Maintaining a separation of one (1) metre between the elevations of the base of the practice and the seasonally high water table, or top of bedrock is recommended. Lesser or greater values may be considered based on groundwater mounding analysis. See [[Groundwater]] for further guidance and spreadsheet tool.


===Pollution Hot Spot Runoff===
===Pollution Hot Spot Runoff===
Line 43: Line 72:
Designers should consult local utility design guidance for the horizontal and vertical clearances required between storm drains.
Designers should consult local utility design guidance for the horizontal and vertical clearances required between storm drains.


===Karst===
===[[Karst]]===
Infiltration trenches, chambers and soakaways are not suitable in areas of known or implied karst topography.  
Infiltration trenches, chambers and soakaways are not suitable in areas of known or implied karst topography.


===Setback from Buildings===
===Setback from Buildings===
Line 128: Line 157:


===Monitoring Wells===  
===Monitoring Wells===  
Recommended for monitoring drainage time between storms.  Monitoring well should be a vertical standpipe consisting of an anchored 100 to 150 mm diameter pipe with perforations along the length within the reservoir, installed to the bottom of the facility, with a lockable cap. Flow-splitting manholes may also be used for drainage time monitoring.
Recommended for monitoring drainage time between storms.  Monitoring wells should be a vertical standpipe consisting of an anchored 100 to 150 mm diameter pipe with perforations along the length within the reservoir, installed to the bottom of the facility, with a lockable cap. Flow-splitting manholes may also be used for drainage time monitoring.


[[File:Monitoring_well.gif]]
[[File:Monitoring_well.gif]]


<small>Simplified cross section of a standard monitoring well.</small><ref> Hawaii State Department of Health. (n.d.). TGM for the Implementation of the Hawai'i State Contingency Plan. Subsection 6.2. MONITORING WELL INSTALLATION AND ABANDONMENT. Retrieved August 27, 2021, from http://hawaiidoh.org/tgm-content/0602a.aspx?f=T </ref>
<small>Simplified cross section of a standard monitoring well.</small><ref> Hawaii State Department of Health. TGM for the Implementation of the Hawai'i State Contingency Plan. Subsection 6.2. MONITORING WELL INSTALLATION AND ABANDONMENT. http://hawaiidoh.org/tgm-content/0602a.aspx?f=T. Published (n.d.). Retrieved August 27, 2021. </ref>
 


===Access Structures===
===Access Structures===
Line 151: Line 179:
|}
|}


==Materials==
==Performance==
===Chambers===
{{:Infiltration chambers: Specifications}}
===Aggregates===
{{:Reservoir gravel}}
===Other===
*[[Geotextiles]]
*[[Pipes]]


===Water Quality===
Take a look at the [[Infiltration Trench: Performance]] page by clicking below for further details about STEPs collected performance results for Infiltratio ntrench practices located within TRCA's, CVC's and LSRCA's watersheds: <br>
</br>
{{Clickable button|[[File:TP effluent comparison.PNG|150 px|link=https://wikidev.sustainabletechnologies.ca/wiki/Infiltration_Trench:_Performance]]}}


==Materials==
==Materials==
===Aggregate===
===Aggregate===
{{:Reservoir aggregate}}
{{:Reservoir aggregate}}
===Other===
*[[Geotextiles]]
*[[Pipes]]


===Perforated Pipe===
===Perforated Pipe===

Latest revision as of 21:50, 6 March 2023

Concrete CurbConcrete CurbRiver RockGeotextile OPSS 1860 Approved FabricPermeable PaverPermeable PaverHigh performance beddingCrushed LimestoneCrushed LimestoneCrushed LimestoneHigh performance beddingWell-graded granular A Material (OPSS 1010)UnderdrainClearstoneClearstoneNative Soil
This infiltration trench features an inlet composed of filter fabric and decorative river stone, which provides some pretreatment and can easily be removed and replaced as part of routine sediment removal maintenance. For more details click here. A note: The following is an "image map", feel free to explore the image with your cursor and click on highlighted labels that appear to take you to corresponding pages on the Wiki.

This article is about underground systems which distribute concentrated flow along a level, linear facility to promote infiltration to native soils.
See exfiltration trenches for guidance on infiltration trench systems integrated with conventional storm sewers and manholes that provide both infiltration and conveyance functions.

Overview[edit]

Images and schematic depicting residential infiltration trenches, commonly referred to as soakaways, that when installed help reduce the risk of flooding and limit negative impacts to stormwater quality.[1]

Infiltration trenches are underground, linear, rectangular or trapezoidal excavations with level or gently sloping bottom grade, geotextile filter fabric on sidewalls and top and filled with clean, crushed angular stone or other void-forming structures. They are well suited to sites where available space for infiltration is limited to strips of land between buildings or properties, or along road rights-of-way. They can also be referred to as infiltration galleries. See Perforated Pipe Systems fact sheet for guidance on infiltration trench systems integrated with conventional storm sewers that provide both infiltration and conveyance functions.

Infiltration trenches are an ideal technology for:

  • Installing below any type of surface or landscape
  • Balancing the requirements to infiltrate excess stormwater whilst conveying excess


Take a look at the downloadable Soakaways, Infiltration Trenches & Chambers Factsheet below for a .pdf overview of this LID Best Management Practice:

Soakaways infiltration et.al.png


The fundamental components of an infiltration trench are:

  • Water storage reservoir, filled with coarse aggregate, possibly void-forming structures to minimize depth and conserve aggregate, and organic material derived from untreated wood (aids in dissolved nitrogen removal);
  • Perforated pipes to deliver water to the trench and convey excess flow to a downstream storm sewer or other BMP; and
  • Geotextile to maintain separation between the storage reservoir and surrounding native soil.

Planning considerations[edit]

As shown in the illustration above a surface inlet to an infiltration trench may simply be a channel of decorative stone supported by a geotextile. So that at grade it may be indistinguishable from a gravel diaphragm. In function though, the decorative surface course of the infiltration trench needs to remain free-draining down into the trench, whereas the gravel diaphragm is designed to spill over onto adjacent land, leaving sediment behind in the gravel or stone channel.

All types of modular infiltration systems require a bedding of angular clear stone to permit infiltration, and provide a foundation for the installation:

  • Plastic chambers usually have a parabolic shape to support the load above. The spaces between rows of plastic pipes or chambers are filled with clear stone to support overlying structures.
  • Concrete vaults and plastic crates are often rectangular-shaped. Concrete vault systems can, in some circumstances, be employed without any additional cover. However, a minimum of 20 cm cover is recommended for most applications. Where this cover is planting soil this can support turf grass. Greater planting soil depths are required to support more deeply rooting plants like perennials and shrubs (45 to 60 cm) and trees (85 to 100 cm).

Native Soil[edit]

Infiltration trenches, chambers and soakaways can be constructed over any soil type, but hydrologic soil group (HSG) A or B soils are best for achieving water balance and erosion control objectives. Facilities should be located on portions of the site with the highest infiltration rates. Native soil infiltration rate at the proposed facility location and depth should be confirmed through in-situ measurements of hydraulic conductivity under field saturated conditions.

Wellhead Protection[edit]

Facilities receiving road or parking lot runoff should not be located within two (2) year time-of-travel wellhead protection areas (see drinking water source protection plan).

Available Space[edit]

Recommended under parking, walkway or landscape areas and require little surface space, solely for inlets, outlets and access structures.

Site Topography[edit]

Facilities cannot be located on natural slopes greater than 15%.

Water Table[edit]

Maintaining a separation of one (1) metre between the elevations of the base of the practice and the seasonally high water table, or top of bedrock is recommended. Lesser or greater values may be considered based on groundwater mounding analysis. See Groundwater for further guidance and spreadsheet tool.

Pollution Hot Spot Runoff[edit]

To protect groundwater from possible contamination, runoff from pollution hot spots should not be treated by infiltration trenches, chambers or soakaways.

Proximity to Underground Utilities[edit]

Designers should consult local utility design guidance for the horizontal and vertical clearances required between storm drains.

Karst[edit]

Infiltration trenches, chambers and soakaways are not suitable in areas of known or implied karst topography.

Setback from Buildings[edit]

Facilities should be setback a minimum of four (4) metres from building foundations.

Design[edit]

Sizing[edit]

Infiltration: Sizing and modeling

  • Virginia up to 10' (3 m) deep. [2]
  • Minnesota up to 12' (3.6 m) deep. [3]
  • "...not normally deeper than 3 to 4 m in order to maximise the length of the flow path to the water table through the unsaturated zone." [4]
  • There is a cost implication with designing deeper practices. If >2.0 m deep, trench shorings are required to support the side walls during construction.

Geometry and Site Layout[edit]

Infiltration chambers and soakaways can be designed in a variety of shapes, although facilities should have level or nearly level bottoms to spread flow evenly throughout. Typically designed with an impervious drainage area to pervious facility footprint area ratio (i.e. I:P ratio) between 5:1 on low permeability soils (HSG C & D) to 20:1 on high permeability soils (HSG A & B). Not typically deeper than 4 m.

Site Layout Requirements for Infiltration Chambers, Trenches and Soakaways
LID Stormwater Management Practice Depth to high water

table or bedrock (m)

Typical Ratio of

Impervious Drainage Area

to Treatment Facility Area

Native Soil Infiltration Rate

(mm/hr)3

Head Space Slope Pollution Hotspots* Set backs**
Soakaway,

infiltration trench

or infiltration chamber

1 5:1 to 20:1 Not a constraint 1 to 2 0 to 1 < 15% No B, U, T, W

*Is the LID SWM BMP practice suitable to be located in known pollution hot spots or runoff source areas where land uses or activities have the potential to generate highly contaminated runoff? This could include fueling centers, demolition zones, outdoor storage or handling areas that house hazardous materials, etc. fueling, servicing or demolition areas, outdoor storage or handling areas for hazardous materials and some heavy industry sites).

**Setback codes: B = Building foundation; U = Underground utilities; T = Trees; W = drinking water wellhead protection areas.

Inlets[edit]

Recommended to distribute inflow between multiple inlets to reduce risk of failure. May include delivery of runoff to the facility as concentrated overland or concentrated underground (i.e. pipe) flow. For concentrated overland flow:

  • Catch basins or other inlet structures should be located at all sag points in the gutter grade and immediately upgrade of median breaks, crosswalks and street intersections,
  • inlet types include curb openings, side inlet catch basins, trench drains, and other pre-fabricated inlet structures,
  • spillways aid in turning flow 30, 45 or 90 degrees into the practice,
  • if the inlet structure itself does not provide sedimentation or filtration pre-treatment, incorporate a geotextile and stone filter inlet at curb opening or spillway locations to isolate sediment, trash and debris for ease of removal, and
  • provide a 50 to 100 mm drop in elevation between inlet invert and top elevation of the stone cover.

For concentrated underground flow, inlets may include plastic or concrete pipes from roof drains or catch basins, storm sewers, OGSs or outlet leader from an upstream BMP. Solid pipe transitions to perforated pipe within the storage reservoir 0.3 m from the sides. Trench plugs should be installed around solid pipes where they enter and exit the storage reservoir.

Pre-Treatment[edit]

It is important to prevent sediment, trash and debris from entering infiltration facilities because they could contribute to clogging and failure of the system. Infiltration practices may be used to treat runoff from roofs and pavements with sedimentation or filtration pre-treatment. The following pre-treatment options help facilitate maintenance and reduce risk of failure by confining sediment and debris to an accessible area, thereby reducing the potential for system clogging:

  • Leaf screens are mesh screens installed either on the building eavestroughs or roof downspouts and are used to remove leaves and other large debris from roof runoff.
  • Catch basin, manhole or other inlet structure sumps in combination with a shield, baffle, trap, or filter insert device, or goss trap, are used to pre-treat concentrated overland flow. They can be designed to retain both coarse and fine particulate sediments in the sump, and floatables (hydrocarbons, trash and debris). A variety of proprietary pre-treatment devices are available.
  • Oil and grit (hydrodynamic) separators (OGS) are used for concentrated underground flow.
  • Infiltration chambers are designed with an isolated filter row at inlets, not connected by pipes to the other chambers, that isolates the bulk of sediment and associated pollutants and is designed for ease of access by jet flushing cleaning equipment.
  • Grass swales can be used to pre-treat road and parking lot runoff . Provide a 75 to 150 mm elevation drop between the inlet invert and swale surface.
  • Geotextile and stone filter inlets are, square or rectangular curb openings located directly over the practice, filled with clean aggregate, covered with a layer of geotextile filter fabric and stone, graded level and installed at concentrated overland flow inlets. Elevation change of 75 to 100 mm from pavement to top of the stone cover. Stone cover may be 50 to 150 mm diameter crushed angular stone, river rock/beach stone or rip rap.

Storage Reservoir[edit]

Depth must meet both runoff storage and structural support requirements. See STEP LID Planning and Design Guide wiki page, Infiltration: Sizing and modeling, for guidance and spreadsheet tool for determining the reservoir depth and area required to store the design storm runoff volume. Should be filled with uniformly graded, washed 25 or 50 mm diameter crushed angular stone (max. wash loss of 0.5%) with a porosity of 0.4. For facilities located under load-bearing structures like pavements, aggregate should have a minimum durability index of 35, and a maximum abrasion of 10% for 100 revolutions and 50% for 500 revolutions. Include organic material derived from untreated wood (e.g. chips, mulch or shavings) to enhance nitrogen removal.

Void-forming structures[edit]

Includes chambers, vaults, crates or perforated pipes that provide large water storage volume per unit area, reduce required facility footprint area and conserve aggregate. Plastic chamber systems should be compliant with CSA B184 SERIES 11 (R2015) or ASTM F2418-16A. Maximum allowable load for plastic chambers must be determined in accordance with ASTM F2787-13. Concrete vault systems should be compliant with CSA A23.3-14 and CSA A23.1-09/A23.2-09 (R2014) or ASTM C858-10e1. See manufacturer for product specific specifications regarding maximum load, minimum cover depth and porosity or water storage per unit area.

Geotextile[edit]

Storage reservoirs should be lined on the sides and top with geotextile filter fabric to maintain separation from the native soil. Geotextile on the base is optional but may be prone to blinding and eventual clogging. Material specifications should conform to Ontario Provincial Standard Specification (OPSS) 1860 for Class II geotextile fabrics. Should be woven monofilament or non-woven needle punched, or woven monofilament with a minimum overlap of 300 mm. Woven slit film and non-woven heat bonded fabrics should not be used as they are prone to clogging. Specification of geotextile fabrics should consider the apparent opening size (AOS) for non-woven fabrics, or percent open area (POA) for woven fabrics, to maintain water flow even with sediment and microbial film build-up. Other factors that need consideration include maximum forces to be exerted on the fabric, and the load bearing ratio, texture (i.e., grain size distribution) and permeability of the native soil in which they will be installed. Geotextile socks around perforated pipes should conform to ASTM D6707 with minimum water flow rate conforming to ASTM D4491 (12,263 L/min/m2 at 5 cm head).

Perforated pipes[edit]

Continuously perforated, smooth interior HDPE or PVC drainage pipe, ≥200 mm interior diameter where possible to reduce risk of freezing and facilitate push camera inspection and cleaning with jet nozzle equipment. Including geotextile socks around perforated pipes is optional. May include an orifice plate or valve flow restrictor to provide erosion control and optimize infiltration.

Conveyance and Overflow[edit]

Typically designed to be offline where a flow control structure or inlet allows only the design storm runoff volume to enter the facility. Excess flows are conveyed to a downstream storm sewer or other BMP by a flow-splitting manhole (i.e. flow through riser) containing a weir and overflow outlet pipe, or by by-passing the curb opening and flowing into a down-gradient catch basin. Overflow structures must be sized to safely convey large event flows. The overflow outlet should be below the maximum frost penetration depth (i.e. frost line) to function year round.

Monitoring Wells[edit]

Recommended for monitoring drainage time between storms. Monitoring wells should be a vertical standpipe consisting of an anchored 100 to 150 mm diameter pipe with perforations along the length within the reservoir, installed to the bottom of the facility, with a lockable cap. Flow-splitting manholes may also be used for drainage time monitoring.

Monitoring well.gif

Simplified cross section of a standard monitoring well.[5]

Access Structures[edit]

Manholes or maintenance hatches connected to infiltration chambers, or standpipe inspection ports connected to infiltration trench or soakaway perforated pipe that provide access for inspection and maintenance. Should be installed at inlets and outlets at a minimum. Couplings used for standpipe connections should be 45° to facilitate pipe access by push camera and jet nozzle cleaning equipment.

Ability to Meet Stormwater Criteria[edit]

BMP Type Water Balance Water Quality Erosion Control
Infiltration Trenches,

Chambers and Soakaways

Yes Yes Yes

Performance[edit]

Water Quality[edit]

Take a look at the Infiltration Trench: Performance page by clicking below for further details about STEPs collected performance results for Infiltratio ntrench practices located within TRCA's, CVC's and LSRCA's watersheds:

TP effluent comparison.PNG

Materials[edit]

Aggregate[edit]

Note the uniform size and angularity of this clear stone sample. Note also that the fragments all appear to have a film of fine particles adhering; this material would be improved by being washed prior to use.

This article gives recommendations for aggregate to be used to store water for infiltration. This is usually called 'clear stone' at aggregate yards.

To see an analysis of Ontario Standard Specifications for granular materials, see OPSS aggregates.

For advice on decorative surface aggregates see Stone


Gravel used for underdrains in bioretention, infiltration trenches and chambers, and exfiltration trenches should be 20 or 50 mm, uniformly-graded, clean (maximum wash loss of 0.5%), crushed angular stone that has a porosity of 0.4[6].

The clean wash to prevent rapid accumulation of fines from the aggregate particles in the base of the reservoir. The uniform grading and the angularity are important to maintain pore throats and clear voids between particles. (i.e. achieve the porosity). Porosity and permeability are directly influenced by the size, gradation and angularity of the particles [7]. See jar test for on-site verification testing protocols.

Gravel with structural requirements should also meet the following criteria:

  • Minimum durability index of 35
  • Maximum abrasion of 10% for 100 revolutions and maximum of 50% for 500 revolutions

Standard specifications for the gradation of aggregates are maintained by ASTM D2940


Other[edit]

Perforated Pipe[edit]

Pipes are available with perforations on just one side, these should be situated on the lower half of the pipe. Pipes with 360° perforations should have a strip of geotextile or membrane placed over the pipe to reduce the migration of fines from overlying media.

Perforated pipes are a common component of underdrains used in bioretention, permeable pavements, infiltration trenches and exfiltration systems.

Pipes should be manufactured in conformity with the latest standards by the Canadian Standards Association (CSA) or ASTM International.

  • Perforated pipes should be continuously perforated, smooth interior HDPE or PVC.
    • Wherever possible pipes should be ≥200 mm internal diameter to reduce potential of freezing and to facilitate push camera inspections and cleaning with jet nozzle equipment.
    • Smooth interior facilitates inspection and maintenance activities; internal corrugations can cause cameras or hydrojetting apparatus to become snagged.
    • A perforated pipe with many rectangular slots has better drainage characteristics than a pipe with similar open area provided by fewer circular holes [8].
  • Non-perforated pipes should be used for conveyance of stormwater to and from the facility, including overflow. It is good practice to extend the solid pipe approximately 300 mm within the reservoir or practice to reduce the potential for native soil migration into the pipe.

See also: Flow through perforated pipe


Construction[edit]

Oil Disturbance and Compaction[edit]

Before site work begins, locations of facilities should be clearly marked. Ideally, infiltration practice locations should remain outside the limit of disturbance until construction of the facility begins to prevent soil compaction by heavy equipment.

Excavation[edit]

If >2.0 m in depth, trench shorings will be required to support the sidewalls. Use a toothed bucket to excavate and roughen the excavation bottom and sides prior to backfilling.

Erosion and Sediment Control[edit]

Infiltration practice locations should not be used as sediment basins during construction. To prevent sediment from clogging, erosion and sediment controls should remain in place and runoff should be diverted from the infiltration facility until the contributing drainage area is fully stabilized and sediment removal from catch basins, pre-treatment devices and maintenance hole sumps has been completed.

Operation and Maintenance[edit]

Infiltration trenches, chambers and soakaways will continue to function during winter months if the overflow outlet is located below the local maximum frost penetration depth (i.e. frost line).

Routine inspection and maintenance consists of checking and cleaning trash, debris and sediment from pre-treatment devices, inlets and outlets twice a year in the spring and/or late fall, or when pre-treatment device sump is half full. Use hydro-vac truck to remove sediment from catch basin sumps, OGS and isolated chamber row filter pre-treatment devices. To clean isolated chamber row filters use a vacuum truck equipped with rear-facing jet nozzle for cleaning large diameter pipes or culverts.

Monitoring of storage reservoir water level during and after natural or simulated storm events using the monitoring well should be performed periodically to verify the facility drains within the required drainage time (typically 72 hours). Should be performed as part of inspections following construction or major rehabilitation prior to assumption, and every 15 years at a minimum, to track drainage performance over time and determine when replacement is needed.


See also *Construction

Gallery[edit]


  1. The City of Windsor. Stormwater Solutions: Infiltration Trenches. https://www.citywindsor.ca/residents/environment/climate-change-adaptation/climate-resilient-home/Documents/Infiltration%20Trench.pdf. Updated 2021. Accessed 30 August, 2021
  2. Viriginia Department of Transport. (2010). VDOT BMP Design Manual of Practice. Retrieved March 15, 2018, from http://www.virginiadot.org/business/resources/LocDes/BMP_Design-Manual/Chapter_8_Infiltration_Trench.pdf
  3. Design criteria for Infiltration trench. (2016, September 21). Minnesota Stormwater Manual, . Retrieved 13:25, April 4, 2018 from https://stormwater.pca.state.mn.us/index.php?title=Design_criteria_for_Infiltration_trench&oldid=28702.
  4. Design of soakaways (2015) www.tiipublications.ie/library/DN-DNG-03072-01.pdf
  5. Hawaii State Department of Health. TGM for the Implementation of the Hawai'i State Contingency Plan. Subsection 6.2. MONITORING WELL INSTALLATION AND ABANDONMENT. http://hawaiidoh.org/tgm-content/0602a.aspx?f=T. Published (n.d.). Retrieved August 27, 2021.
  6. Porosity of Structural Backfill, Tech Sheet #1, Stormtech, Nov 2012, http://www.stormtech.com/download_files/pdf/techsheet1.pdf accessed 16 October 2017
  7. 7.0 7.1 7.2 Judge, Aaron, "Measurement of the Hydraulic Conductivity of Gravels Using a Laboratory Permeameter and Silty Sands Using Field Testing with Observation Wells" (2013). Dissertations. 746. http://scholarworks.umass.edu/open_access_dissertations/746
  8. Hazenberg, G., and U. S. Panu (1991), Theoretical analysis of flow rate into perforated drain tubes, Water Resour. Res., 27(7), 1411–1418, doi:10.1029/91WR00779.