| [[File:monitoring-well-subgrade.jpg|400px|thumb|right|Monitoring well stack installed next to underdrain within the LID practice.]] | | [[File:monitoring-well-subgrade.jpg|400px|thumb|right|Monitoring well stack installed next to underdrain within the LID practice.]] |
| ====Monitoring Wells==== | | ====Monitoring Wells==== |
| [[Monitoring wells]] allow for measurement of water levels in the sub-surface components of LID practices. They are important for sampling procedures and ensuring that the LID feature are performing as intended.<br> | | [[Monitoring wells]] allow for measurement of water levels in the sub-surface components of LID practices. They are important for sampling procedures and ensuring that the LID feature are performing as intended. |
|
| |
|
| '''Construction Steps:'''<br> | | '''Construction Steps:''' |
| #Install a cap stand at the required elevation to anchor the monitoring well. | | #Install a cap stand at the required elevation to anchor the monitoring well. |
| #Wrap the perforated pipe with a geotextile sock (to prevent migration of soil into the well). | | #Wrap the perforated pipe with a geotextile sock (to prevent migration of soil into the well). |
| #Anchor the perforated pipe to the bottom of the LID feature. | | #Anchor the perforated pipe to the bottom of the LID feature. |
| #Install a lockable cap to the top of the standpipe to protect against vandalism. | | #Install a lockable cap to the top of the standpipe to protect against vandalism. |
| #Install monitoring equipment (e.g., a level logger) if required.<br> | | #Install monitoring equipment (e.g., a level logger) if required. |
|
| |
|
| '''Key Inspection Points:'''<br> | | '''Key Inspection Points:''' |
| *Pipe is perforated, rigid, and matches design specifications. | | *Pipe is perforated, rigid, and matches design specifications. |
| *Well is installed according to contract documents. | | *Well is installed according to contract documents. |
| *Geotextile sock is wrapped around the perforated portion of the well.<br> | | *Geotextile sock is wrapped around the perforated portion of the well. |
|
| |
|
| '''Mistakes to Avoid:'''<br> | | '''Mistakes to Avoid:''' |
| *Incorrect sequencing – ensure that standpipe is installed prior to backfilling with granular material.<br> | | *Incorrect sequencing – ensure that standpipe is installed prior to backfilling with granular material. |