*f<sub>f, min</sub> = minimum infiltration rate (i.e. saturated hydraulic conductivity) of the filter media (m/h), see [[Bioretention: Filter media|Filter media]] for guidance}}<br>
*f<sub>f, min</sub> = minimum infiltration rate (i.e. saturated hydraulic conductivity) of the filter media (m/h), see [[Bioretention: Filter media|Filter media]] for guidance}}<br>
For practices where flow is delivered directly to the storage reservoir:
For practices where flow is delivered directly to the storage reservoir:
<math>A_{p}=i\times D\times A_{i}/[d_{a} + (f' \times D)]</math>
<math>A_{p}=i\times D\times A_{i}/[d_{i} + (f' \times D)]</math>
{{Plainlist|1=Where:
{{Plainlist|1=Where:
*d<sub>a</sub> = Active water storage depth (m), see above for equations for with and without underdrain designs
*d<sub>i</sub> = Infiltration water storage depth (m), see above for equations for with and without underdrain designs
*f' = design infiltration rate of the underlying native soil (m/h)
*f' = design infiltration rate of the underlying native soil (m/h)
*D = Design storm duration (h)}}<br>
*D = Design storm duration (h)}}<br>