===Spacing drainage pipes to reduce groundwater mounding===
===Spacing drainage pipes to reduce groundwater mounding===
[[File:Drain spacing.jpg|thumb|The yellow box represents the recommended hydraulic conductivity of bioretention filter media]]
[[File:Drain spacing.jpg|thumb|The yellow box represents the recommended hydraulic conductivity of bioretention filter media]]
In most LID underdrain applications, lateral drains should be spaced between 5 - 6 m apart.
In most LID underdrain applications, lateral drains should be spaced between 5 - 6 m apart. This recommendation is supported by an analysis of Hooghoudt's equation <ref>H.P.Ritzema, 1994, Subsurface flow to drains. Chapter 8 in: H.P.Ritzema (ed.), Drainage Principles and Applications, Publ. 16, pp. 236-304, International Institute for Land Reclamation and Improvement (ILRI), Wageningen, The Netherlands. ISBN 90-70754-33-9</ref><ref>W.H. van der Molen en J.Wesseling, 1991. A solution in closed form and a series solution to replace the tables for the thickness of the equivalent layer in Hooghoudt's drain spacing equation. Agricultural Water Management 19, pp.1-16</ref><ref>van Beers, W.F.J. 1976, COMPUTING DRAIN SPACINGS: A generalized method with special reference to sensitivity analysis
----
This recommendation is supported by an analysis of Hooghoudt's equation <ref>H.P.Ritzema, 1994, Subsurface flow to drains. Chapter 8 in: H.P.Ritzema (ed.), Drainage Principles and Applications, Publ. 16, pp. 236-304, International Institute for Land Reclamation and Improvement (ILRI), Wageningen, The Netherlands. ISBN 90-70754-33-9</ref><ref>W.H. van der Molen en J.Wesseling, 1991. A solution in closed form and a series solution to replace the tables for the thickness of the equivalent layer in Hooghoudt's drain spacing equation. Agricultural Water Management 19, pp.1-16</ref><ref>van Beers, W.F.J. 1976, COMPUTING DRAIN SPACINGS: A generalized method with special reference to sensitivity analysis
and geo-hydrological investigations, International Institute for Land Reclamation and Improvement (ILRI) Wageningen, The Netherlands</ref> in relation to loamy or clayey native soils, where ''K<sub>media</sub>''>>''K<sub>soil</sub>'', finds the first term of the numerator negligible, so that the original equation:
and geo-hydrological investigations, International Institute for Land Reclamation and Improvement (ILRI) Wageningen, The Netherlands</ref> in relation to loamy or clayey native soils, where ''K<sub>media</sub>''>>''K<sub>soil</sub>'', finds the first term of the numerator negligible, so that the original equation:
<math>Drain\ spacing=\sqrt{\frac{8K_{soil}H\left(D_{i}-D_{d}\right)\left(D_{d}-D_{w}\right)+4K_{soil}\left(D_{d}-D_{w}\right)^{2}}{q}}</math>
<math>Drain\ spacing=\sqrt{\frac{8K_{soil}H\left(D_{i}-D_{d}\right)\left(D_{d}-D_{w}\right)+4K_{soil}\left(D_{d}-D_{w}\right)^{2}}{q}}</math>
Line 13: Line 11:
*''D<sub>w</sub>'' is the minimum acceptable depth to the water table during infiltration event
*''D<sub>w</sub>'' is the minimum acceptable depth to the water table during infiltration event
*''q'' is the inflow volume expressed as a depth over the entire surface (m)}}
*''q'' is the inflow volume expressed as a depth over the entire surface (m)}}
----

Latest revision as of 14:32, 13 June 2019

Spacing drainage pipes to reduce groundwater mounding[edit]

The yellow box represents the recommended hydraulic conductivity of bioretention filter media

In most LID underdrain applications, lateral drains should be spaced between 5 - 6 m apart. This recommendation is supported by an analysis of Hooghoudt's equation [1][2][3] in relation to loamy or clayey native soils, where Kmedia>>Ksoil, finds the first term of the numerator negligible, so that the original equation: may be simplified to:

Where:

  • Kmedia is expressed in m/day
  • Dd is the depth to the drain pipe (m)
  • Dw is the minimum acceptable depth to the water table during infiltration event
  • q is the inflow volume expressed as a depth over the entire surface (m)

  1. H.P.Ritzema, 1994, Subsurface flow to drains. Chapter 8 in: H.P.Ritzema (ed.), Drainage Principles and Applications, Publ. 16, pp. 236-304, International Institute for Land Reclamation and Improvement (ILRI), Wageningen, The Netherlands. ISBN 90-70754-33-9
  2. W.H. van der Molen en J.Wesseling, 1991. A solution in closed form and a series solution to replace the tables for the thickness of the equivalent layer in Hooghoudt's drain spacing equation. Agricultural Water Management 19, pp.1-16
  3. van Beers, W.F.J. 1976, COMPUTING DRAIN SPACINGS: A generalized method with special reference to sensitivity analysis and geo-hydrological investigations, International Institute for Land Reclamation and Improvement (ILRI) Wageningen, The Netherlands