→Calculate drawdown time
Line 55:
Line 55:
:<math>t=\frac{nA_{p}}{f'P}ln\left [ \frac{\left (d_{T}+ \frac{A_{p}}{P} \right )}{\left(\frac{A_{p}}{P}\right)}\right]</math>
:<math>t=\frac{nA_{p}}{f'P}ln\left [ \frac{\left (d_{T}+ \frac{A_{p}}{P} \right )}{\left(\frac{A_{p}}{P}\right)}\right]</math>
{{Plainlist|1=Where:
{{Plainlist|1=Where:
*''n'' is the porosity of the
media
,
*''n'' is the porosity of the
fill materials within the practice
,
depth weighted mean
*''A<sub>p</sub>'' is the area of the practice (m<sup>2</sup>),
*''A<sub>p</sub>'' is the area of the practice (m<sup>2</sup>),
*''f''' is the design infiltration rate (mm/hr),
*''f''' is the design infiltration rate (mm/hr),