Line 7: Line 7:
#[[Bioretention]] has a maximum recommended catchment impervious area to practice permeable (footprint) area ratio, R (or I/P ratio) of 20.
#[[Bioretention]] has a maximum recommended catchment impervious area to practice permeable (footprint) area ratio, R (or I/P ratio) of 20.


==Size a bioretention cell for constrained depth==
==Size a bioretention cell with no underdrain for constrained depth==
If there is a constraint to the depth (''d<sub>T</sub>'', m) of the practice, calculate the required footprint area (''A<sub>p</sub>'', m<sup>2</sup>), as:
If there is a constraint to the depth (''d<sub>T</sub>'', m) of the practice, calculate the required footprint area (''A<sub>p</sub>'', m<sup>2</sup>), as:
<math>A_{p}=\frac{A_i\times i\times D}{(n\times d_{T})+(f'\times D)}</math>
<math>A_{p}=\frac{A_i\times i\times D}{(n\times d_{T})+(f'\times D)}</math>