Changes

Jump to navigation Jump to search
Line 118: Line 118:
* Step 10: Calculate the surface (i.e footprint) area of the practice (A<sub>p</sub>) needed to capture the runoff volume produced from the catchment during the design storm event<br>
* Step 10: Calculate the surface (i.e footprint) area of the practice (A<sub>p</sub>) needed to capture the runoff volume produced from the catchment during the design storm event<br>
For practices where flow is delivered to a surface ponding area:
For practices where flow is delivered to a surface ponding area:
<math>A_{p}=i\times D\times A_{i}/[d_{p}' + (f_{m, min} \times D)]</math>
<math>A_{p}=i\times D\times A_{i}/[d_{p}' + (f_{f, min} \times D)]</math>
{{Plainlist|1=Where:
{{Plainlist|1=Where:
*i = Design storm intensity (m/h)
*i = Design storm intensity (m/h)
Line 124: Line 124:
*A<sub>i</sub> = Catchment impervious area (m<sup>2</sup>)
*A<sub>i</sub> = Catchment impervious area (m<sup>2</sup>)
*d<sub>p</sub>' = Design surface ponding depth (m)
*d<sub>p</sub>' = Design surface ponding depth (m)
*f<sub>m, min</sub> = minimum infiltration rate (i.e. saturated hydraulic conductivity) of the filter media (m/h), see [[Bioretention: Filter media|Filter media]] for guidance}}<br>
*f<sub>f, min</sub> = minimum infiltration rate (i.e. saturated hydraulic conductivity) of the filter media (m/h), see [[Bioretention: Filter media|Filter media]] for guidance}}<br>
For practices where flow is delivered directly to the storage reservoir:
For practices where flow is delivered directly to the storage reservoir:
<math>A_{p}=i\times D\times A_{i}/[d_{a} + (f' \times D)]</math>
<math>A_{p}=i\times D\times A_{i}/[d_{a} + (f' \times D)]</math>

Navigation menu