| | This article describes recommended design approaches when available space for the practice is constrained.<br> |
| | <br> |
| | Before beginning the sizing calculations certain parameters must be known or estimated. See [[Bioretention: Sizing]] for parameter descriptions and conceptual diagram illustrating key components of bioretention practices. Note that some of these parameters are limited: |
| | #The ''maximum'' total depth will be limited by construction practices i.e. not usually > 2 m. |
| | #The ''maximum'' total depth may be limited by the [[Infiltration| conditions underground]] e.g. the groundwater or underlying geology/infrastructure. |
| | #The minimum total depth will be limited by the need to support vegetation (e.g not less than 0.6 m to support deep rooting perennials and shrubs). |
| | #[[Bioretention]] has a maximum recommended catchment impervious area to practice permeable (footprint) area ratio, R (or I/P ratio) of 20. |
|
| |
|
| <ol>
| | ==Size a bioretention cell receiving flows directly to the storage reservoir for a constrained depth== |
| <li>Gather input data:
| | If there is a constraint to the depth (''d<sub>T</sub>'') of the practice, calculate the required storage reservoir footprint area (''A<sub>r</sub>''), as: |
| <ul>
| | <math>A_{r}=\frac{i\times D\times A_i}{(d_{r}\times n')+(f'\times D)}</math> |
| <li>The applicable infiltration coefficient (q) is calculated by applying the safety factor to the [[Infiltration: Testing|measured infiltration rate]].</li>
| | {{Plainlist|1=Where: |
| <li>Determine the drainage catchment area (A<sub>D</sub>), and outline the location of the bioretention facility. To begin with, budget for at least 10% of the contributing impervious area to be required for the BMP. </li></li>
| | *''A<sub>r</sub>'' = Area of the infiltration practice storage reservoir (m<sup>2</sup>) |
| <li>Unless the biomedia fill material has been tested and certified otherwise, a porosity value (V<sub>r</sub>) of 0.4 may be assumed (i.e. void ratio 40%). </li> | | *''A<sub>i</sub>'' = Catchment impervious area (m<sup>2</sup>) |
| <li>Bioretention facilities are usually between 0.5 m and 1.25 m deep, owing to construction considerations. Determine the maximum available depth (c<sub>c max</sub>) from the site constraints. The [[Infiltration]] page lists these. </li>
| | *''D'' = Duration of design storm (h) |
| <li>Identify the duration (D) and intensity (i) of design storm(s). </li></ul> | | *''i'' = Intensity of design storm (mm/h) |
| <li>Calculate the required area</li>
| | *''f''' = [[design infiltration rate]] (m/h) |
| </ol> | | *''n''' = Effective porosity of the fill material in the storage reservoir of the practice |
| <ThirdLeft>
| | *''d<sub>r</sub>'' = Storage reservoir depth, based on depth available between the elevation of the invert of the underdrain perforated pipe and one (1) metre above the seasonally high water table or top of bedrock (m) or other value determined to be suitable through groundwater mounding analysis.}}<br> |
| <panelWarning>
| | If R is greater than 20, consider decreasing catchment impervious area (A<sub>i</sub>) by draining less area to the practice. |
| <strong>[[Media:Infiltration Sizing.xlsx|Download .xlsx calculation tool]]</strong>
| |
| </panelWarning>
| |
| </ThirdLeft><TwoThirdRight></TwoThirdRight><clearFix></clearFix> | |
| <clearFix></clearFix> | |
|
| |
|
| <a href=[[Media:Infiltration Sizing.xlsx]]>Click me!!!</a>
| | ==Size a bioretention cell where drainage area and practice area are fixed== |
| | If the land area is limited, determine the I/P ratio, which is the ratio of catchment impervious area (A<sub>i</sub>) to practice pervious footprint area (A<sub>p</sub>): |
| | :<math>R=\frac{A_{i}}{A_{p}}</math> |
|
| |
|
| <form method="post" action="[[Media:Infiltration Sizing.xlsx]]"> | | {{Plainlist|1= Where: |
| <button type="success">Download .xlsx tool</button>
| | *''R'' = Ratio of catchment impervious area to practice pervious footprint area, also referred to as I/P ratio |
| </form> | | *''A<sub>p</sub>'' = Practice pervious footprint area in m<sup>2</sup> |
| | *''A<sub>i</sub>'' = Catchment impervious area in m<sup>2</sup>}} |
| | |
| | Then calculate the required storage reservoir depth (''d<sub>r</sub>''), as: |
| | <math>d_{r}=\frac{D \left[ (R\times i)-f'\right]}{n'}</math> |
| | |
| | {{Plainlist|1=Where: |
| | *''D'' = Duration of design storm (h) |
| | *''i'' = Intensity of design storm (m/h) |
| | *''f''' = Design infiltration rate (m/h) |
| | *''n''' = Effective porosity of the storage reservoir fill material}} |
| | These equations assume that infiltration occurs primarily through the base of the facility.<br> |
| | <br> |
| | This spreadsheet tool has been set up to perform all of the infiltration practice sizing calculations shown above.<br> |
| | {{Clickable button|[[Media:Infiltration Sizing 20200525 locked.xlsx|Download the infiltration practice sizing tool]]}} |
| | |
| | ==Calculate drawdown time== |
| | [[file:Hydraulic radius.png|thumb|Two footprint areas of 9 m<sup>2</sup>.<br> |
| | Perimeter = 12 m (left) Perimeter = 20 m (right)]] |
| | |
| | {{Clickable button|[[Media:Darcy drainage_20200528_locked.xlsx|Download the Darcy drainage time calculator tool]]}} |
| | |
| | In some situations, it may be possible to reduce the size of the bioretention required, by accounting for rapid drainage. Typically, this is only worth exploring over sandy soils with rapid infiltration. |
| | Note that narrow, linear bioretention features drain faster than round or blocky footprint geometries. |
| | *Begin the drainage time calculation by dividing the storage reservoir area of the practice (''A<sub>r</sub>'') by the perimeter (''x''). |
| | *Use the following equation to estimate the time (''t'') to fully drain the facility: |
| | :<math>t=\frac{nA_{r}}{f'x}ln\left [ \frac{\left (d_{r}+ \frac{A_{r}}{x} \right )}{\left(\frac{A_{r}}{x}\right)}\right]</math> |
| | {{Plainlist|1=Where: |
| | *''n'' is the porosity of the storage reservoir fill material |
| | *''A<sub>r</sub>'' is the storage reservoir footprint area (m<sup>2</sup>), |
| | *''f''' is the design infiltration rate of the native soil (mm/h), |
| | *''x'' is the perimeter of the practice (m), and |
| | *''d<sub>r</sub>'' is the depth of the storage reservoir (m).}} |
| | |
| | This 3 dimensional equation makes use of the hydraulic radius (''A<sub>r</sub>''/''x''), where ''x'' is the perimeter (m) of the facility. <br> |
| | Maximizing the perimeter of the facility directs designers towards longer, linear shapes such as [[bioswales]]. |
| | |
| | [[category: modeling]] |
| | [[category: infiltration]] |