Line 1: |
Line 1: |
| ====Overflows====
| |
| [[Overflow|Overflows]] are features of inline facilities and convey larger storm events out of the LID feature. | | [[Overflow|Overflows]] are features of inline facilities and convey larger storm events out of the LID feature. |
|
| |
|
| '''Construction Steps:''' | | '''Construction Steps:''' |
| #Connect the overflow drain to the underdrain. | | #Connect the overflow drain to the underdrain. |
| | #Fit a metal, domed grate to the overflow. |
| #Install overflow pit to grade at the location specified in the contract documents. | | #Install overflow pit to grade at the location specified in the contract documents. |
| #Fit a metal, domed grate to the overflow.
| |
|
| |
|
| '''Key Inspection Points:''' | | '''Key Inspection Points:''' |
Line 15: |
Line 14: |
|
| |
|
| '''Mistakes to Avoid:''' | | '''Mistakes to Avoid:''' |
| *Backflows – ensure that backflows are avoided by confirming that inlet and overflow elevations match design specifications with surveys. | | *Backflows: Ensure that backflows are avoided by confirming that inlet and overflow elevations match design specifications with surveys. |
| *Incorrect sequencing – install overflow drain prior to backfilling with granular material and engineered soil. | | *Incorrect sequencing: Install overflow drain prior to backfilling with granular material and engineered soil. |
| *Incorrect grate material – avoid using plastic overflow grates due to breakages and UV degradation. | | *Incorrect grate material: Avoid using plastic overflow grates due to breakages and UV degradation. |
|
| |
|
| <gallery mode="packed" widths=300px heights=300px> | | <gallery mode="packed" widths=300px heights=300px> |
| overflow-pipe-install.jpg | Overflow pipe installed to an underdrain T-connection. | | overflow-pipe-install.jpg | Overflow pipe installed to an underdrain T-connection. (Photo Source: CVC, 2010) |
| overflow-plastic-cap.jpg | Overflow installed with a plastic cap. Note that the use of plastic grates is discouraged. | | overflow-plastic-cap.jpg | Overflow installed with a plastic cap. Note that the use of plastic grates is discouraged. (Photo Source: CVC, 2012) |
|
| |
|
| </gallery> | | </gallery> |