*[https://www3.epa.gov/region1/npdes/stormwater/research/epa-final-report-filter-study.pdf (USEPA, 2013) - Evaluation and Optimization of Bioretention Design for Nitrogen and Phosphorus Removal]
[[File:OGS types Lee, 2014 update.PNG|thumb|400px|Shown here are the two variations of hydrodynamic separators ([[Oil and grit separator]]s) used in the 6-year study conducted by Lee, et al., 2014. All four OGS' used were of different sizes. The first (Type A) was a dip cylindrical plate with a centershaft and the second (Type B) was a hollow cylindrical screen. All four sites where the OGS' were installed were in urban settings in Gyunggi Province, Korea, and discharge into Gyung-An stream, which deposits into the Pal-dang Lake. This lake is the the primary drinking water source for Seoul's Metropolitan area (Lee, et al. 2014<ref>Lee, D.H., Min, K.S. and Kang, J.H., 2014. Performance evaluation and a sizing method for hydrodynamic separators treating urban stormwater runoff. Water science and technology, 69(10), pp.2122-2131)</ref>]].
**USEPA conducted both field and laboratory testing on the performance of bioretention with augmented designs and filter media composition with aluminum hydroxide/oxide content, found normally within water treatment residuals. These additives added at 10-15% of the total filter media mix ad median removal efficiencies of 90-99% of orthophosphate and a second study found a bioretention design with WTR mixture in the filter media and a [[Bioretention: Internal water storage|IWSZ]] optimized to remove phosphorus and nitrogen had a removal efficiency of 20% and effluent concentrations below 20µg/L (well below the MECP/CCME guideline in Ontario).


[[File:EBC vs. TBC.PNG|500px|thumb| Comparison of an Enhanced dephosphorization bioretention cell (EBC) (above) vs. a traditional bioretention cell (TBC) (below). The EBC includes evenly spaced apart soil mixture layers, which includes 70-80% native soil found on site mixed with 20-30% of charcoal, oregani matter and iron, along with permeable layers of gravel pumice and zeolite, all of which help adsorb phosphates out of stormwater entering the system. This differs from the TBC design which generally includes just a gravel bed to aid in the facility's drainage ability (Ho and Lin, 2022)<ref>Ho, C.C. and Lin, Y.X., 2022. Pollutant Removal Efficiency of a Bioretention Cell with Enhanced Dephosphorization. Water, 14(3), p.396. https://mdpi-res.com/books/book/5900/Urban_Runoff_Control_and_Sponge_City_Construction.pdf?filename=Urban_Runoff_Control_and_Sponge_City_Construction.pdf#page=168</ref>.]]
*[https://www.conteches.com/Portals/0/Documents/Product%20Evaluation%20and%20%20Testing/vx_harding_township.pdf?ver=2018-05-31-143332-863 (Clary et al., 2020) - International Stormwater BMP Database: 2020 Summary Statistics.]
**The International Stormwater Best Management Practices (BMP) Database is a publicly accessible repository for BMP performance monitoring study, design, and cost information.  As of December 2019, the BMP Database contains data sets collected over four decades from over 700 BMP studies through the U.S., Canada, Sweden, New Zealand, Australia, China, etc. that are accessible on the project website ([www.bmpdatabase.org]). The performance data for both TSS and TP are as follows within the report:
***Median TSS value of outflow/effluent of stormwater from P.P is 22 mg/L in comparison to 77 mg/L influent levels. These levels are computed using the BCa bootstrap method described by Efron and Tibishirani (1993). This value is below the required CCME levels for TSS in stormwater.
***Median Total phosphorus (TP) value of outflow/effluent of stormwater from P.P is 0.10 mg/L in comparison to 0.17 mg/L influent levels. These levels are computed using the BCa bootstrap method described by Efron and Tibishirani (1993). This value is below the required CCME levels for TP in stormwater.


*[https://www.mdpi.com/2073-4441/14/3/396 (Ho and Lin, 2022) - Pollutant Removal Efficiency of a Bioretention Cell with Enhanced Dephosphorization]
<ref>Clary, J., Jones, J., Leisenring, M., Hobson, P. and Strecker, E. 2020. International stormwater BMP database 2020 summary statistics. Water Environment & Reuse Foundation.</ref>).
**Authors Ho and Lin, 2022 note that bioretention practices perform poorly in reducing phosphorus from influent stormwater when compared to their ability to remove ammonia and COD pollutants. The authors tested a new type of enhanced dephosphorization bioretention cell (EBC) which improves phosphorus removal performance. The difference between EBC and a traditional bioretention cell is that the lowest level of an EBC feature is comprised of a mixed fill material layer (permeable layers - PLs and soil mixed layers - SMLs) instead of a traditional gravel bed layer. The SMLs include active charcoal powder, organic matter and iron, evenly spaced apart, while the PLs include aggregates of gravel, pumice and zeolite. Over the two years that the same sized EBC feature was monitored in comparison to a standard bioretention cell they found that the EBC outperformed the traditional bioretention cell by removing 92% of total phosphorus to 52%. The average inflow concentration for both features from May 2019 - April 2021 was 0.76 mg/L, whereas the outflow concentration averages were 0.36 mg/L for the traditional bioretention cell and 0.06 mg/L for the EBC, respectively (Ho and Lin, 2022)<ref>Ho, C.C. and Lin, Y.X., 2022. Pollutant Removal Efficiency of a Bioretention Cell with Enhanced Dephosphorization. Water, 14(3), p.396. https://mdpi-res.com/books/book/5900/Urban_Runoff_Control_and_Sponge_City_Construction.pdf?filename=Urban_Runoff_Control_and_Sponge_City_Construction.pdf#page=168</ref>.


*[https://sustainabletechnologies.ca/app/uploads/2019/06/improving-nutrient-retention-in-bioretention-tech-brief.pdf (STEP, 2019) - Improving nutrient retention in bioretention - Technical Brief]
*[https://www.eeer.org/upload/eer-14-4-262-.pdf (Jianghua, et al. 2009) - Performance Analysis of a Hydrodynamic Separator for Treating Particulate Pollutants in Highway Rainfall Runoff.]
**STEP researchers developed a study to examine the effectiveness of reactive media amendments as a means of enhancing phosphorus retention in a bioretention cell draining a 1150 m<sup>2</sup> parking lot in the City of Vaughan. For testing purposes, the bioretention was divided into three hydrologically distinct cells: (1) with a high sand, low phosphorus media mix (control); (2) with a proprietary reactive media (Sorbitve™) mixed into the sandy filter media, and (3) with a 170 cm layer of iron rich sand (aka red sand) below the sandy filter media. Outflow quantity and quality from each cell was measured directly, while inflows and runoff quality were estimated based on monitoring of an adjacent asphalt reference site over the same time period. The results found that the Sorbitve™ and the Iron rich (red) sand cells had lower concentrations of Total Phosphorus (among other contaminants) in its effluent outflow, and the TP measured was below the CCDME guideline of 0.03mg/L in both years monitored for Sorbitve™ (2016 & 2017) and 2017 for the cell with Iron rich (red) sand. Both cells had median concentrations lower than the control media cell used in the study by at least 68% for TP (STEP, 2019<ref>STEP. 2019. Improving nutrient retention in bioretention - Technical Brief. Prepared by Toronto and Region Conservation Authority. Published in 2018. https://sustainabletechnologies.ca/app/uploads/2019/06/improving-nutrient-retention-in-bioretention-tech-brief.pdf</ref>.
** This study examined the separation characteristics of particles in runoff from paved roads using a OGS hydro cyclone design. The results indicated the TSS concentration ratio between the overflow and inflow (TSSover/in) decreased as a function of the operational pressure and the particle removal efficiency was mainly affected by the particle size. By using highway runoff results showed that removal efficiency was greater than 60%. The TSSover/in was (0.26 mg/L – 0.41 mg/L) below the Canadian Water Quality Guidelines (CWQGs) (Jianghua, et al. 2009<ref>Jianghua, Y., Qitao, Y. and Kim, Y. 2009. Performance analysis of a hydrodynamic separator for treating particulate pollutants in highway rainfall runoff. Environmental Engineering Research, 14(4), pp.262-269. https://www.eeer.org/upload/eer-14-4-262-.pdf</ref>).


*[https://repository.library.noaa.gov/view/noaa/41705/noaa_41705_DS1.pdf (Ament, et al. 2022) - Phosphorus removal, metals dynamics, and hydraulics in stormwater bioretention systems amended with drinking water treatment residuals]
*[https://pubmed.ncbi.nlm.nih.gov/24845330/ (Lee, et al. 2014) - Performance evaluation and a sizing method for hydrodynamic separators treating urban stormwater runoff.]
**Researchers from the University of Minnesota, the University of Vermont and the USEPA, conducted field experiment to test the effectiveness of Drinking water treatment residuals (DWTRs) as a filter media amendment additive for improve Total Phosphorus (TP) removal in roadside bioretention features. Influent phosphorus levels was relatively low when compared to normal influent stormwater P levels (dissolved = 0.002 mg/L, soluble reactive = 0.022, particulate = 0.036 mg/L) but the difference between the bioretention cell in the study with DWTR additives and the control bioretention cells were 95% (Large D.A) - 97% (small D.A) TP removal and 79 (large D.A)and 91% (small D.A) respectively. The outflows were well below the CCME guidelines of 0.3 mg/L coming in at 0.010 mg/L (large D.A) and 0.011mg/L (small D.A) (Ament, et al. 2022)<ref>Ament, M.R., Roy, E.D., Yuan, Y. and Hurley, S.E., 2022. Phosphorus removal, metals dynamics, and hydraulics in stormwater bioretention systems amended with drinking water treatment residuals. Journal of Sustainable Water in the Built Environment, 8(3), p.04022003.</ref>.)
**This study conducted performance monitoring over a 6-year period (137 separate storm events) of four different hydrodynamic separators in Korean urban catchments between 2006 - 2012. Removal rates were relatively low at all four sites (1. Roadway site: Avg. Inflow = 239.32 mg/L vs Avg. Outflow = 122.2- mg/L /  2. Residential site:  Avg. Inflow = 59.74 mg/L vs Avg. Outflow = 50.35 mg/L / 3. Roadway Site: Avg. Inflow = 62.50 mg/L vs. Avg. Outflow = 33.76 mg/L / 4. Residential(63.5%) & Roadway (36.5%) CDA site: Avg. Inflow = 236.24 mg/L vs. Avg. Outflow = 160.54 mg/L). The low removal rates were due to high rates of extreme overflow events occurring with most suspended sediment being quite small/fine in nature (<75μm)(Lee, et al. 2014<ref>Lee, D.H., Min, K.S. and Kang, J.H., 2014. Performance evaluation and a sizing method for hydrodynamic separators treating urban stormwater runoff. Water science and technology, 69(10), pp.2122-2131)</ref>.
 
*[https://www.researchgate.net/publication/332063360_Enhanced_Nutrients_Removal_in_Bioretention_Systems_Modified_with_Water_Treatment_Residual_and_Internal_Water_Storage_Zone/download (Qiu, et al. 2019) - Enhanced Nutrients Removal in Bioretention Systems Modified with Water Treatment Residual and Internal Water Storage Zone]
**Researchers from Beijing University and Auburn University, conducted lab experiments with two bioretention columns (1) with Water treatment residuals (WTRs - i.e. polyaluminium chloride & dewatered sludge from a surface water treatment plant) (15% dried weight, the remaining 85% sandy loam) and the second (2) filled with traditional sandy loam for its filter bed material. Their pollutant rmeova lefficiency for TSS was virtually the same, treating between 100 - 400 mg/L over 10 separate test cycles in a 50-day period. The effluent TSS levels were bot hless than 20 mg/L (10 mg/L less than the CCME requirement in Ontario) with removal percentages above 90% on average to a maximum of 97%. Meanwhile, for Total Phosphorus removal (TP) the column with 15% WTRs added boated a mean TP removal of 99.6% with a maximum effluent of 0.08 mg/L after remoting an average influent concentration load of 4.0 – 7.0 mg/L) (Qiu, et al. 2019)<ref>Qiu, F., Zhao, S., Zhao, D., Wang, J. and Fu, K., 2019. Enhanced nutrient removal in bioretention systems modified with water treatment residuals and internal water storage zone. Environmental Science: Water Research & Technology, 5(5), pp.993-1003.</ref>.


==References==
==References==

Revision as of 20:26, 28 February 2023


TSS Reduction[edit]

TSS - permeable pavement.JPG

The performance results for Permeable pavement/Porous Asphalt: Life Cycle Costs practices, located within TRCA's watershed originate from three primary sites:

  • Kortright Centre Parking Lot
  • Seneca College
  • IMAX Corporation, head office

The mean performance value recorded at the outlet for Permeable Pavement practices' ability to remove Total Suspended Sediments (TSS) was was calculated based on 296 separate recordings between 2005-2007, and 2010-2017 amongst the three sites previously mentioned.

As can be seen in the corresponding boxplot the mean performance removal efficiency of the permeable pavement practices monitored are well below the suggested guideline of 30 mg/L (Canadian Water Quality Guideline (CWQG), or (background (assumed at <5 mg/L)+ 25 mg/L for short term (<24 hour) exposure) (CCME, 2002[1]; (TRCA, 2021[2]).

The median value of the 301 samples taken was 8.95 mg/L whereas the mean was 17.10 mg/L, with a 12% guideline exceedance.

TP - permeable pavement.JPG

Phosphorus Reduction[edit]

The performance results for Permeable pavement/Porous Asphalt: Life Cycle Costs practices, located within TRCA's watershed originate from three primary sites:

  • Kortright Centre Parking Lot
  • Seneca College
  • IMAX Corporation, head office

The mean performance value recorded at the outlet for Permeable Pavement practices' ability to remove Total Phosphorus (TP) was calculated based on 300 separate recordings between 2005-2007, and 2010-2017 amongst the three sites previously mentioned.

As can be seen in the corresponding boxplot, the mean performance removal efficiency of the bioretention practices monitored are not meeting the acceptable upper extent range of nutrients as of 0.03 mg/L (30 µg/L) (Environment Canada, 2004[3]; OMOEE, 1994[4]).

The median value of the 355 samples taken was 0.04 mg/L whereas the mean was 0.08 mg/L, with a 62% guideline exceedance. Given the age of most of these practices, more inspection, maintenance and necessary rehabilitation will be needed to ensure they are able to meet the federal and provincial governments' guideline requirement for stormwater quality.

Please refer to the Phosphorus page and the additives page for more information on how LIDs can reduce contaminant loading in stormwater

Recent Performance Research[edit]

Shown here are the two variations of hydrodynamic separators (Oil and grit separators) used in the 6-year study conducted by Lee, et al., 2014. All four OGS' used were of different sizes. The first (Type A) was a dip cylindrical plate with a centershaft and the second (Type B) was a hollow cylindrical screen. All four sites where the OGS' were installed were in urban settings in Gyunggi Province, Korea, and discharge into Gyung-An stream, which deposits into the Pal-dang Lake. This lake is the the primary drinking water source for Seoul's Metropolitan area (Lee, et al. 2014[5]

.

  • (Clary et al., 2020) - International Stormwater BMP Database: 2020 Summary Statistics.
    • The International Stormwater Best Management Practices (BMP) Database is a publicly accessible repository for BMP performance monitoring study, design, and cost information. As of December 2019, the BMP Database contains data sets collected over four decades from over 700 BMP studies through the U.S., Canada, Sweden, New Zealand, Australia, China, etc. that are accessible on the project website ([www.bmpdatabase.org]). The performance data for both TSS and TP are as follows within the report:
      • Median TSS value of outflow/effluent of stormwater from P.P is 22 mg/L in comparison to 77 mg/L influent levels. These levels are computed using the BCa bootstrap method described by Efron and Tibishirani (1993). This value is below the required CCME levels for TSS in stormwater.
      • Median Total phosphorus (TP) value of outflow/effluent of stormwater from P.P is 0.10 mg/L in comparison to 0.17 mg/L influent levels. These levels are computed using the BCa bootstrap method described by Efron and Tibishirani (1993). This value is below the required CCME levels for TP in stormwater.

[6]).

  • (Lee, et al. 2014) - Performance evaluation and a sizing method for hydrodynamic separators treating urban stormwater runoff.
    • This study conducted performance monitoring over a 6-year period (137 separate storm events) of four different hydrodynamic separators in Korean urban catchments between 2006 - 2012. Removal rates were relatively low at all four sites (1. Roadway site: Avg. Inflow = 239.32 mg/L vs Avg. Outflow = 122.2- mg/L / 2. Residential site: Avg. Inflow = 59.74 mg/L vs Avg. Outflow = 50.35 mg/L / 3. Roadway Site: Avg. Inflow = 62.50 mg/L vs. Avg. Outflow = 33.76 mg/L / 4. Residential(63.5%) & Roadway (36.5%) CDA site: Avg. Inflow = 236.24 mg/L vs. Avg. Outflow = 160.54 mg/L). The low removal rates were due to high rates of extreme overflow events occurring with most suspended sediment being quite small/fine in nature (<75μm)(Lee, et al. 2014[8].

References[edit]

  1. Canadian Council of Ministers of the Environment (CCME). 2002. Canadian water quality guidelines for the protection of aquatic life: Total particulate matter. In: Canadian Environmental Quality Guidelines, Canadian Council of Ministers of the Environment, Winnipeg
  2. TRCA. 2021. Spatial Patterns (2016-2020) and Temporal Trends (1966-2020) in Stream Water Quality across TRCA’s Jurisdiction Prepared by Watershed Planning and Ecosystem Science. https://trcaca.s3.ca-central-1.amazonaws.com/app/uploads/2021/10/29113334/2016-2020-SWQ-Report-v11_FINAL_AODA-FA.pdf
  3. Environment Canada. (2004). Canadian guidance framework for the management of phosphorus in freshwater systems. Ecosystem Health: Science‐based solutions report no. 1–8. Cat. No. En1–34/8–2004E.
  4. Ontario Ministry of Environment and Energy (OMOEE), 1994. Policies, Guidelines and Provincial Water Quality Objectives of the Ministry of Environment and Energy. Queen’s Printer for Ontario. Toronto, ON.
  5. Lee, D.H., Min, K.S. and Kang, J.H., 2014. Performance evaluation and a sizing method for hydrodynamic separators treating urban stormwater runoff. Water science and technology, 69(10), pp.2122-2131)
  6. Clary, J., Jones, J., Leisenring, M., Hobson, P. and Strecker, E. 2020. International stormwater BMP database 2020 summary statistics. Water Environment & Reuse Foundation.
  7. Jianghua, Y., Qitao, Y. and Kim, Y. 2009. Performance analysis of a hydrodynamic separator for treating particulate pollutants in highway rainfall runoff. Environmental Engineering Research, 14(4), pp.262-269. https://www.eeer.org/upload/eer-14-4-262-.pdf
  8. Lee, D.H., Min, K.S. and Kang, J.H., 2014. Performance evaluation and a sizing method for hydrodynamic separators treating urban stormwater runoff. Water science and technology, 69(10), pp.2122-2131)