    <p>This type of bioretention facility provides the highest level of stormwater volume control.  Although this design does not include an underdrain, an overflow pipe, a weir or other outlet structure must be included. </p>
This type of bioretention facility provides the highest level of stormwater volume control.  Although this design does not include an underdrain, an overflow pipe, a weir or other outlet structure must be included.
----
==Performance==
===Performance===
{{:Bioretention: Water quality}}
{{:Bioretention: Water quality}}
----
==Materials==
 
{{textbox|{{plainlist|
===Materials===
*[[Reservoir gravel]]
<ol>
*[[Pea gravel]]
<li>[[Reservoir gravel]]</li>
*[[Geotextiles]]
<li>[[Pea gravel]]</li>
*[[Pipes]]
<li>[[Geotextiles]]</li>
*[[Biomedia]]
<li>[[Pipes]]</li>
*[[Erosion control blankets|Erosion control]]
<li>[[Biomedia]]</li>
*[[Mulch|Mulch]]
<li>[[Erosion control blankets|Erosion control]]</li>
*[[Bioretention: Planting plans|Planting considerations]] and [[Bioretention: Plant list| Recommended species]]}}}}
<li>[[Mulch|Mulch]]</li>
<li>[[Bioretention: Planting plans|Planting considerations]] and [[Bioretention: Plant list| Recommended species]]</li>
</ol>
----
</div>
<div class="col-md-4">
    <panelInfo>
        <gallery mode="packed" widths=300px heights=300px>
Full infiltration.png|Fully infiltrating bioretention with an inspection well, but no underdrain
        </gallery>
    </panelInfo>
</div>
<div class="col-md-12">
 
[[Bioretention cells|<i class="fa fa-level-up" aria-hidden="true"></i><strong>Back to bioretention</strong>]]
[[Bioretention cells|<i class="fa fa-level-up" aria-hidden="true"></i><strong>Back to bioretention</strong>]]
{{:Feedback}}
[[category:Infiltration]]
[[category:Infiltration]]

Revision as of 01:51, 12 August 2017

Fully infiltrating bioretention with an inspection well, but no underdrain

Overview[edit]

This type of bioretention facility provides the highest level of stormwater volume control. Although this design does not include an underdrain, an overflow pipe, a weir or other outlet structure must be included.

Performance[edit]

Bioretention: Water quality

Materials[edit]

Back to bioretention