Difference between revisions of "Rainwater harvesting: TTT"
Jump to navigation
Jump to search
Jenny Hill (talk | contribs) (Created page with "400 px|link=http://www.sustainabletechnologies.ca/wp/low-impact-development-treatment-train-tool/ Once the size of cistern has been determined, it can easily...") |
Jenny Hill (talk | contribs) |
||
Line 3: | Line 3: | ||
Once the size of cistern has been determined, it can easily be modeled in many open source and proprietary applications. For planning purposes, a RWH system could be integrated into a site plan using STEP's Treatment Train Tool. This tool provides a graphical user interface and simplified inputs on the EPA SWMM model. It is free to download, click image above. | Once the size of cistern has been determined, it can easily be modeled in many open source and proprietary applications. For planning purposes, a RWH system could be integrated into a site plan using STEP's Treatment Train Tool. This tool provides a graphical user interface and simplified inputs on the EPA SWMM model. It is free to download, click image above. | ||
In a typical configuration: | In a typical configuration: | ||
{|class="mw-collapsible mw-collapsed wikitable" | |||
|- | |||
|Catchment (roof)||100% impervious | |||
|- | |||
|colspan = 2| The rainwater harvesting system would be a 'Storage' Element with the following properties: | |||
|- | |||
|Storage type||No removal | |||
|- | |||
|?||Lined | |||
|- | |||
|Underlying soil||<em>Doesn't matter</em> | |||
|- | |||
|Evaporation factor||0 | |||
|- | |||
|Suction head (mm)||0 | |||
|- | |||
|Saturated conductivity (mm/hr)||0 | |||
|- | |||
|Initial soil moisture deficit (fraction)||0 | |||
|- | |||
|colspan = 2|The dimensions of the rainwater cistern can be placed into the fields: | |||
#Bottom elevation (m) | #Bottom elevation (m) | ||
#Maximum depth (m) | #Maximum depth (m) | ||
#Initial water depth (m) | #Initial water depth (m) | ||
#The Curves table is designed to accommodate ponds of roughly conical dimensions. A rainwater cistern is usually cuboid or cylindrical in shape, so that the area (m<sup>2</sup>) will remain the same throughout the depth. | #The Curves table is designed to accommodate ponds of roughly conical dimensions. A rainwater cistern is usually cuboid or cylindrical in shape, so that the area (m<sup>2</sup>) will remain the same throughout the depth. | ||
|} | |||
[[category:modeling]] | [[category:modeling]] |
Revision as of 02:04, 8 September 2017
Once the size of cistern has been determined, it can easily be modeled in many open source and proprietary applications. For planning purposes, a RWH system could be integrated into a site plan using STEP's Treatment Train Tool. This tool provides a graphical user interface and simplified inputs on the EPA SWMM model. It is free to download, click image above. In a typical configuration:
Catchment (roof) | 100% impervious |
The rainwater harvesting system would be a 'Storage' Element with the following properties: | |
Storage type | No removal |
? | Lined |
Underlying soil | Doesn't matter |
Evaporation factor | 0 |
Suction head (mm) | 0 |
Saturated conductivity (mm/hr) | 0 |
Initial soil moisture deficit (fraction) | 0 |
The dimensions of the rainwater cistern can be placed into the fields:
|