Difference between revisions of "Structural practices summary"
Jump to navigation
Jump to search
Line 1: | Line 1: | ||
{|class="wikitable" | {| class="wikitable" style="width: 150%; height: 200px;" | ||
|+ LID Design Guide Detail | |||
|- | |- | ||
! | !style="background: cyan; color: black"| | ||
| | !style="background: cyan; color: black"|Available Space | ||
!style="background: cyan; color: black"|Site Topography | |||
!style="background: cyan; color: black"|Available Head | |||
!style="background: cyan; color: black"|Soils | |||
!style="background: cyan; color: black"|Pollution Hot Spot Runoff | |||
!style="background: cyan; color: black"|Setbacks from Buildings | |||
!style="background: cyan; color: black "|Proximity to Underground Utilities | |||
!style="background: cyan; color: black"|Set Backs | |||
!style="background: cyan; color: black"|Drainage Area and Runoff Volume | |||
!style="background: cyan; color: black"|Wellhead Protection | |||
!style="background: cyan; color: black"|Water Table | |||
!style="background: cyan; color: black"|Overhead Wires | |||
!style="background: cyan; color: black"|Flow Path Length Across Impermeable Surface | |||
!style="background: cyan; color: black"|Winter Operations | |||
!style="background: cyan; color: black"|Vehicle Loading | |||
!style="background: cyan; color: black"|Structural Requirements | |||
!style="background: cyan; color: black"|Roof Slope | |||
|- | |- | ||
! | ![[Roof Downspout Disconnection]] | ||
| | |Simple downspout disconnection requires a minimum flow path length across the pervious area (at least 5 metres) and suitable soil conditions. If the flow path length is less than 5 metres and soils are hydrologic soil group (HSG) C or D, roof downspouts should be directed to another LID practice such as a rainwater harvesting system, soakaway, swale, bioretention area or perforated pipe system. | ||
|Disconnected downspouts should discharge to a gradual slope that conveys runoff away from the building. The slope should be between 1% and 5%. Grading should discourage flow from reconnecting with adjacent impervious surfaces | |||
| | |||
|If the infiltration rate of soils in the pervious area is less than 15 mm/hr, they should be tilled to a depth of 300 mm and amended with compost to achieve an organic content in the range of 8 to 15% by weight or 30 to 40% by volume. | |||
|Downspout disconnection can be used where land uses or activities at ground-level have the potential to generate highly contaminated runoff as long as the roof runoff is kept separate from runoff from groundlevel impervious surfaces | |||
| | |||
| | |||
|- | |- | ||
! | !Cistern | ||
| | !Not applicable | ||
!|1:1||Not applicable||0||0||0||Yes||None||None||None | |||
|- | |- | ||
! | !Roof Downspout Disconnection | ||
| | !Not applicable | ||
!|[5 to 100 m<sup>2</sup>]||Amend if < 15 mm/hr||0.5||5 to 20||1 to 5||Yes||Building Foundation||None||None | |||
|- | |- | ||
! | !Soakaway, Infiltration Trench or Chamber | ||
| | !1 | ||
!|5:1 to 20:1||Not a constraint||1 to 2||0 to 1||<15 %||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||1 m||2 yr | |||
|- | |- | ||
! | !Bioretention | ||
| | !1 | ||
!|5:1 to 15:1||Underdrain required<br>if < 15 mm/hr||1 to 2||5 to 10||0 to 2||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||1 m||2 yr | |||
|- | |- | ||
! | !Biofilter (Filtration only Bioretention Design) | ||
| | !Not applicable | ||
!|5:1||Not applicable||1 to 2||2 to 5||0 to 2||Yes||Building Foundation, Trees||None||None | |||
|- | |- | ||
! | !Vegetated Filter Strip | ||
| | !1 | ||
!|5:1||Amend if < 15 mm/hr||0 to 1||15 to 20||1 to 5||No||None||None||None | |||
|- | |- | ||
! | !Permeable Pavement | ||
| | !1 | ||
!|1:1 to 1.2:1||Underdrain Required <br> if < 15 mm/hr||0.5 to 1||0||1 to 5||No||4m-Underground Utilities<br>Drinking Water Wellhead<br>Protection Areas||1 m||2 Yr | |||
|- | |- | ||
! | !Enhanced Grass Swale | ||
| | !1 | ||
!|5:1 to 10:1||Not applicable||1 to 3||5 to 15||0.5 to 6||No||4m- Building Foundation<br>Underground Utilities||1 m||None | |||
|- | |- | ||
! | !Dry Swale (Bioswale) | ||
| | !1 | ||
!|5:1 to 15:1||Underdrain Required <br> if < 15 mm/hr||1 to 3||5 to 10||0.5 to 6||No||4m (3m if impermeable liner<br>is used)Building foundation,<br> Underground utilities, drinking<br>water wellhead protection areas||1 m||2 Yr | |||
|- | |||
!Perforated Pipe System | |||
!1 | |||
!|5:1 to 10:1||Not a constraint||1 to 3||0||< 15%||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||1 m||2 Yr | |||
|} | |} |
Revision as of 18:08, 19 September 2017
Available Space | Site Topography | Available Head | Soils | Pollution Hot Spot Runoff | Setbacks from Buildings | Proximity to Underground Utilities | Set Backs | Drainage Area and Runoff Volume | Wellhead Protection | Water Table | Overhead Wires | Flow Path Length Across Impermeable Surface | Winter Operations | Vehicle Loading | Structural Requirements | Roof Slope | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Roof Downspout Disconnection | Simple downspout disconnection requires a minimum flow path length across the pervious area (at least 5 metres) and suitable soil conditions. If the flow path length is less than 5 metres and soils are hydrologic soil group (HSG) C or D, roof downspouts should be directed to another LID practice such as a rainwater harvesting system, soakaway, swale, bioretention area or perforated pipe system. | Disconnected downspouts should discharge to a gradual slope that conveys runoff away from the building. The slope should be between 1% and 5%. Grading should discourage flow from reconnecting with adjacent impervious surfaces | If the infiltration rate of soils in the pervious area is less than 15 mm/hr, they should be tilled to a depth of 300 mm and amended with compost to achieve an organic content in the range of 8 to 15% by weight or 30 to 40% by volume. | Downspout disconnection can be used where land uses or activities at ground-level have the potential to generate highly contaminated runoff as long as the roof runoff is kept separate from runoff from groundlevel impervious surfaces | |||||||||||||
Cistern | Not applicable | 1:1 | Not applicable | 0 | 0 | 0 | Yes | None | None | None | |||||||
Roof Downspout Disconnection | Not applicable | [5 to 100 m2] | Amend if < 15 mm/hr | 0.5 | 5 to 20 | 1 to 5 | Yes | Building Foundation | None | None | |||||||
Soakaway, Infiltration Trench or Chamber | 1 | 5:1 to 20:1 | Not a constraint | 1 to 2 | 0 to 1 | <15 % | No | 4m- Building Foundation Underground Utilities, Trees, Drinking Water Wellhead Protection Areas |
1 m | 2 yr | |||||||
Bioretention | 1 | 5:1 to 15:1 | Underdrain required if < 15 mm/hr |
1 to 2 | 5 to 10 | 0 to 2 | No | 4m- Building Foundation Underground Utilities, Trees, Drinking Water Wellhead Protection Areas |
1 m | 2 yr | |||||||
Biofilter (Filtration only Bioretention Design) | Not applicable | 5:1 | Not applicable | 1 to 2 | 2 to 5 | 0 to 2 | Yes | Building Foundation, Trees | None | None | |||||||
Vegetated Filter Strip | 1 | 5:1 | Amend if < 15 mm/hr | 0 to 1 | 15 to 20 | 1 to 5 | No | None | None | None | |||||||
Permeable Pavement | 1 | 1:1 to 1.2:1 | Underdrain Required if < 15 mm/hr |
0.5 to 1 | 0 | 1 to 5 | No | 4m-Underground Utilities Drinking Water Wellhead Protection Areas |
1 m | 2 Yr | |||||||
Enhanced Grass Swale | 1 | 5:1 to 10:1 | Not applicable | 1 to 3 | 5 to 15 | 0.5 to 6 | No | 4m- Building Foundation Underground Utilities |
1 m | None | |||||||
Dry Swale (Bioswale) | 1 | 5:1 to 15:1 | Underdrain Required if < 15 mm/hr |
1 to 3 | 5 to 10 | 0.5 to 6 | No | 4m (3m if impermeable liner is used)Building foundation, Underground utilities, drinking water wellhead protection areas |
1 m | 2 Yr | |||||||
Perforated Pipe System | 1 | 5:1 to 10:1 | Not a constraint | 1 to 3 | 0 | < 15% | No | 4m- Building Foundation Underground Utilities, Trees, Drinking Water Wellhead Protection Areas |
1 m | 2 Yr |