Line 1: |
Line 1: |
| Content here about retention and detention in landscape depressions.
| | Also known as infiltration basins. |
| | |
| | ==Overview== |
| | Dry ponds are recommended as flood control structures to accommodate occasional excess overflow downstream of other structural BMPs. They should be integrated into the landscape as useful, accessible public space. |
| | |
| | |
| | |
| | ==Design== |
| | The surface storage volume of a dry pond is simply determined: |
| | |
| | <math>A_{pond}=\frac{\left (RVC_T\times A_{catchment}\right)}{\left ( q\times t_{drawdown}\right )}</math> |
| | |
| | |
| | |
| [[Flood control]] | | [[Flood control]] |