*Determine stone size by flow velocities at inlets and outlets. Typical stone for this purpose ranges between 50 mm and 250 mm. The larger the stone, the more energy dissipation.
*Determine stone size by flow velocities at inlets and outlets. Typical stone for this purpose ranges between 50 mm and 250 mm. The larger the stone, the more energy dissipation.
*Stone beds should be twice as thick as the largest stone's diameter.
*Stone beds should be twice as thick as the largest stone's diameter.
*To prevent erosion of soils beneath the stone and the migration of the stone into the soil, the stone bed should be underlain by a drainage [[geotextile]].
*To prevent erosion of soils beneath the stone and the migration of the stone into the soil, the stone bed should be underlain by a drainage [[Geotextiles|geotextile]].


Direct and spread flow throughout a large LID facility or to protect narrow channel sections where flow will concentrate
Direct and spread flow throughout a large LID facility or to protect narrow channel sections where flow will concentrate

Revision as of 15:55, 19 December 2017

File:FILL IN
This rain garden in a school yard uses stone as both decorative edging and for erosion control.
File:IMAX Stone Inlet.jpg
This bioswale in a parking lot uses stone at the inlets and along the bottom of the swale to prevent erosion, as the sides are sloped.

For advice on aggregates used in Underdrains, see Gravel

Stone can serve as a low maintenance decorative feature, but it may also serve practical functions in an LID practice. Typical stone functions in LID and direction on selection:

Dissipate flow and prevent erosion at inlets and outlets

  • Angular crushed stone, which will "knit" or lock together and be less likely to shift, is recommended. However, for aesthetic purposes, smooth river-run stone may be desired.
  • Determine stone size by flow velocities at inlets and outlets. Typical stone for this purpose ranges between 50 mm and 250 mm. The larger the stone, the more energy dissipation.
  • Stone beds should be twice as thick as the largest stone's diameter.
  • To prevent erosion of soils beneath the stone and the migration of the stone into the soil, the stone bed should be underlain by a drainage geotextile.

Direct and spread flow throughout a large LID facility or to protect narrow channel sections where flow will concentrate

  • While crushed stone will be less likely to shift, river-run stone may be used to create a dry-stream-bed look.
  • The sizing of the gravel will depend on the expected velocities.