Difference between revisions of "Flow through perforated pipe"
Jump to navigation
Jump to search
Jenny Hill (talk | contribs) m |
Jenny Hill (talk | contribs) m |
||
Line 1: | Line 1: | ||
Manufacturers of perforated pipe are often able to provide the open area (m<sup>2</sup>) per meter length. | Manufacturers of perforated pipe are often able to provide the open area (m<sup>2</sup>) per meter length. | ||
<math>Q_{max, p}=B\times C_{d}\times A_{o}\sqrt{2\cdot g\cdot \sum d | <math>Q_{max, p}=B\times C_{d}\times A_{o}\sqrt{2\cdot g\cdot \sum d}</math> | ||
{{Plainlist|1=Where: | {{Plainlist|1=Where: | ||
*''K<sub>m</sub>'' is the hydraulic conductivity of the filter media (mm/hr), | *''K<sub>m</sub>'' is the hydraulic conductivity of the filter media (mm/hr), | ||
Line 7: | Line 7: | ||
*''d<sub>p</sub>'' is the depth of ponding (mm), | *''d<sub>p</sub>'' is the depth of ponding (mm), | ||
*''d<sub>m</sub>'' is the depth of the filter media (mm), and | *''d<sub>m</sub>'' is the depth of the filter media (mm), and | ||
*''Σ d | *''Σ d'' is the total depth of bioretention components over the perforated pipe (mm) (e.g. ponding/[[mulch]]/[[filter media]]/[[choker layer]]), | ||
}} | }} |
Revision as of 02:15, 25 February 2018
Manufacturers of perforated pipe are often able to provide the open area (m2) per meter length.
Where:
- Km is the hydraulic conductivity of the filter media (mm/hr),
- Ap is the area of the practice (m2),
- dp is the depth of ponding (mm),
- dm is the depth of the filter media (mm), and
- Σ d is the total depth of bioretention components over the perforated pipe (mm) (e.g. ponding/mulch/filter media/choker layer),