Difference between revisions of "Flow through an orifice"
Jump to navigation
Jump to search
Jenny Hill (talk | contribs) (Created page with " <math>Q= B\times C_{d}\times A_{o}\sqrt{2\cdot g\cdot h}</math> {{Plainlist|1=Where: *''L'' is the length of perforated pipe (m) *''B'' is the clogging factor (between 0.5...") |
Jenny Hill (talk | contribs) m |
||
Line 12: | Line 12: | ||
}} | }} | ||
== | ==See also== | ||
*[[Flow through | *[[Flow through perforated pipe]] | ||
[[category: Calculations]] | [[category: Calculations]] |
Revision as of 22:36, 20 November 2018
Where:
- L is the length of perforated pipe (m)
- B is the clogging factor (between 0.5 (for matured installation) and 1 (for a new perfectly performing BMP)),
- Cd is the coefficient of discharge (usually 0.61 for a plate, or 0.8 for a pipe),
- Ao is the area of the orifice (m2/m),
- g is acceleration due to gravity = 9.81 m/s2, and
- h is the head of water over the centre of the orifice.