Difference between revisions of "Planters: Sizing"
Jump to navigation
Jump to search
Dean Young (talk | contribs) |
Dean Young (talk | contribs) |
||
(6 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
[[File:Sizing flow-through planter.jpg|thumb|A flow-through planter comprises a ponding zone, mulch layer, filter media for planting, and a supporting gravel drainage layer]] | [[File:Sizing flow-through planter.jpg|thumb|A flow-through planter comprises a ponding zone, mulch layer, filter media for planting, and a supporting gravel drainage layer]] | ||
This article is specific to flow-through stormwater planters, vegetated systems that do not infiltrate water to the native soil. <br> | This article is specific to flow-through [[Stormwater planters|stormwater planters]], vegetated systems that do not infiltrate water to the native soil. <br> | ||
If you are designing a planted system which does infiltrate water, see advice on [[Bioretention: Sizing]]. | If you are designing a planted system which does infiltrate water, see advice on [[Bioretention: Sizing]]. | ||
Line 19: | Line 19: | ||
| | | | ||
* 0.7 for wood based | * 0.7 for wood based | ||
* 0.4 for | * 0.4 for stone | ||
|- | |- | ||
| [[Bioretention: Filter media|Filter media]] (''d<sub>m</sub>'') | | [[Bioretention: Filter media|Filter media]] (''d<sub>m</sub>'') | ||
Line 26: | Line 26: | ||
* 600 mm to support shrubs, flowering [[perennials]] and decorative [[grasses]] | * 600 mm to support shrubs, flowering [[perennials]] and decorative [[grasses]] | ||
* 1000 mm to support [[trees]] | * 1000 mm to support [[trees]] | ||
| 0.35 | | | ||
* 0.35 for Blend A - Drainage rate priority; | |||
* 0.4 for Blend B - Water quality treatment priority | |||
|- | |- | ||
| Pipe diameter reservoir | | Pipe diameter reservoir | ||
Line 36: | Line 38: | ||
| 0.4 | | 0.4 | ||
|} | |} | ||
Latest revision as of 01:54, 14 July 2020
This article is specific to flow-through stormwater planters, vegetated systems that do not infiltrate water to the native soil.
If you are designing a planted system which does infiltrate water, see advice on Bioretention: Sizing.
The dimensions of a stormwater planter are largely predetermined according to the function of the component. As they do not contain a storage reservoir the planters rely more upon careful selection of materials. Both the filter media and the perforations of the pipe play critical roles for flow control.
Component | Recommended depth (with underdrain pipe) | Typical porosity (n) |
---|---|---|
Ponding (dp) | 150 to 450 mm | 1 |
Mulch | 75 ± 25 mm |
|
Filter media (dm) |
|
|
Pipe diameter reservoir | Is equal to underdrain pipe diameter | 0.4 |
Pipe bedding (db) | 50 mm (although commonly omitted altogether). | 0.4 |