This comes from the | This comes from the | ||
''"The depth to bedrock should be greater than or equal to 1 metre below the bottom of the perforated pipe storage media to ensure adequate drainage/hydraulic potential" | ''"The depth to bedrock should be greater than or equal to 1 metre below the bottom of the perforated pipe storage media to ensure adequate drainage/hydraulic potential"<ref name=MOE2003>https://www.ontario.ca/document/stormwater-management-planning-and-design-manual/stormwater-management-plan-and-swmp-design</ref>'' | ||
''"If a pervious pipe system is implemented in an area where the seasonally high water table is higher than the obvert of the pipe, the pipe will drain the groundwater table. In this scenario, depending on the native soil characteristics and whether the trench or pipe is wrapped in geotextile fabric, soil can be transported into the pipe system undermining the pipe foundation and leading to structural failure. Pervious pipe systems should not be implemented in areas where the seasonal high groundwater level is within 1 metre of the bottom of the storm sewer backfill to ensure this does not happen." | ''"If a pervious pipe system is implemented in an area where the seasonally high water table is higher than the obvert of the pipe, the pipe will drain the groundwater table. In this scenario, depending on the native soil characteristics and whether the trench or pipe is wrapped in geotextile fabric, soil can be transported into the pipe system undermining the pipe foundation and leading to structural failure. Pervious pipe systems should not be implemented in areas where the seasonal high groundwater level is within 1 metre of the bottom of the storm sewer backfill to ensure this does not happen."<ref name=MOE2003/>'' | ||
Both of these considerations are equally relevant to the [[underdrain]] of any structural BMP. | Both of these considerations are equally relevant to the [[underdrain]] of any structural BMP. | ||
Other relevant | |||
<ref>Province of Ontario. “O. Reg. 332/12: BUILDING CODE,” 2018. https://www.ontario.ca/laws/regulation/120332.</ref> | <ref>Province of Ontario. “O. Reg. 332/12: BUILDING CODE,” 2018. https://www.ontario.ca/laws/regulation/120332.</ref> | ||
Revision as of 17:53, 12 April 2019
In Ontario the vertical separation between a practice and the water table or bedrock is frequently cited as 1 meter. This comes from the
"The depth to bedrock should be greater than or equal to 1 metre below the bottom of the perforated pipe storage media to ensure adequate drainage/hydraulic potential"[1]
"If a pervious pipe system is implemented in an area where the seasonally high water table is higher than the obvert of the pipe, the pipe will drain the groundwater table. In this scenario, depending on the native soil characteristics and whether the trench or pipe is wrapped in geotextile fabric, soil can be transported into the pipe system undermining the pipe foundation and leading to structural failure. Pervious pipe systems should not be implemented in areas where the seasonal high groundwater level is within 1 metre of the bottom of the storm sewer backfill to ensure this does not happen."[1] Both of these considerations are equally relevant to the underdrain of any structural BMP.
Other relevant [2]
- ↑ 1.0 1.1 https://www.ontario.ca/document/stormwater-management-planning-and-design-manual/stormwater-management-plan-and-swmp-design
- ↑ Province of Ontario. “O. Reg. 332/12: BUILDING CODE,” 2018. https://www.ontario.ca/laws/regulation/120332.
- ↑ Karathanasis, A D, T G Mueller, B Boone, and Y L Thompson. “Nutrient Removal from Septic Effluents as Affected by Soil Thickness and Texture.” Journal of Water and Health 4, no. 2 (June 2006): 177–95. http://www.ncbi.nlm.nih.gov/pubmed/16813011.
- ↑ Stall, Christopher, Aziz Amoozegar, David Lindbo, Alexandria Graves, and Diana Rashash. “Transport of E. Coli in a Sandy Soil as Impacted by Depth to Water Table.” Journal of Environmental Health 76, no. 6: 92–100. Accessed October 23, 2018. http://www.ncbi.nlm.nih.gov/pubmed/24645419.
- ↑ RI Department of Environmental Management. “Section 5.5.1 and 5.5.4 RISDISM Guidance -- Filtering Systems: Separation to Seasonal High Groundwater Table,” 2016.
- ↑ Ontario. “F-6-1 Procedures to Govern Separation of Sewers and Watermains | Ontario.Ca,” 2016. https://www.ontario.ca/page/f-6-1-procedures-govern-separation-sewers-and-watermains.
- ↑ Rathfelder, K., and M. Wei. “Underground Stormwater Infiltration: Best Practice for Protection of Groundwater Resources in British Columbia,” 2014. http://www.env.gov.bc.ca/wsd/plan_protect_sustain/groundwater/library.html
- ↑ Washington St.ate Department of Ecology. “Guidance for UIC Wells That Manage Stormwater,” 2006.