Difference between revisions of "Permeable pavements: Specifications"
Jump to navigation
Jump to search
(Created page with "{|class="wikitable" |+ specifications for pervious concrete, porous asphalt, and permeable pavers. |- !style="background: cyan; color: black"|Material !style="background: cy...") |
|||
Line 1: | Line 1: | ||
{|class="wikitable" | {|class="wikitable" | ||
|+ | |+ <h2>[[Specifications for pervious concrete, porous asphalt, and permeable pavers]] </h2> | ||
|- | |- | ||
Line 9: | Line 9: | ||
!Pervious Concrete | !Pervious Concrete | ||
|* 28 day compressive strength = 5.5 to 20 MPa <br> * Void ratio = 14% - 31%<br>* Permeability = 900 - 21,500 mm/hr||Thickness will range from 100-150 mm depending on the expected loads | |* 28 day compressive strength = 5.5 to 20 MPa <br> * Void ratio = 14% - 31%<br>* Permeability = 900 - 21,500 mm/hr||Thickness will range from 100 mm-150 mm depending on the expected loads | ||
|- | |- | ||
!Porous Asphalt | !Porous Asphalt | ||
|* open-graded asphalt mix with a minimum of 16% air voids <br> * Polymer can be added to provide additional strength to heavy loads||Thickness will range from 50 mm-100 mm depending on the expected loads | |||
|- | |||
!Permeable Pavers | |||
|*ASTM No. 8(5 mm dia) crused aggregate is recommended for fill material in the paver openings.<br>*Pavers shall meet the minimum material and standard specification for Precast Concrete Pavers.<br>*Pigment in concrete pavers shall conform to ASTM C 979 ACI Report No. 212.3R provides guidance on the use of pigments.<br>*Maximum allowable breakage of product is 5%||*For vehicle applications the minimum paver thickness is 80 mm<br>*For pedestrian applications is 60 mm and Joint widths should be no greater than 15 mm. | |||
|- |
Revision as of 13:26, 20 September 2017
Material | Specification | Quantity |
---|---|---|
Pervious Concrete | * 28 day compressive strength = 5.5 to 20 MPa * Void ratio = 14% - 31% * Permeability = 900 - 21,500 mm/hr |
Thickness will range from 100 mm-150 mm depending on the expected loads |
Porous Asphalt | * open-graded asphalt mix with a minimum of 16% air voids * Polymer can be added to provide additional strength to heavy loads |
Thickness will range from 50 mm-100 mm depending on the expected loads |
Permeable Pavers | *ASTM No. 8(5 mm dia) crused aggregate is recommended for fill material in the paver openings. *Pavers shall meet the minimum material and standard specification for Precast Concrete Pavers. *Pigment in concrete pavers shall conform to ASTM C 979 ACI Report No. 212.3R provides guidance on the use of pigments. *Maximum allowable breakage of product is 5% |
*For vehicle applications the minimum paver thickness is 80 mm *For pedestrian applications is 60 mm and Joint widths should be no greater than 15 mm. |