Check dams are small dams or weirs constructed across a drainage ditch, swale, or channel to lower the speed of concentrated flows for a certain design range of storm events and to promote infiltration.
- Check dams usually consist of crushed rock gabions, or pre-treated timber up to 0.6 m in height.
- Rocks used in check dams should have median diameter 25-75 mm.
- The spacing of dams should not exceed the horizontal distance from the toe of the upstream dam to the same elevation on the downstream dam.
- Where check dams are used, the maximum design depth of ponded water must be 0.5 m.