Difference between revisions of "Geotextiles"

From LID SWM Planning and Design Guide
Jump to navigation Jump to search
Line 11: Line 11:
</ol>
</ol>


<table class="table table-bordered">
<table class = "table-responsive">
<table class="table table-striped">
<caption><strong>Recommended criteria for selection of geotextile fabric</strong></caption>  
<caption><strong>Recommended criteria for selection of geotextile fabric</strong></caption>  
<tr class="success"><th>Percent media passing 0.075 mm (#200 sieve)</th><th>Non-woven fabric apparent opening size (AOS, mm)</th><th>Woven fabric percent open area (POA, %)</th><th>Permittivity (sec<sup>-1</sup>)</th></tr>
<tr class="success"><th>Percent media passing 0.075 mm (#200 sieve)</th><th>Non-woven fabric apparent opening size (AOS, mm)</th><th>Woven fabric percent open area (POA, %)</th><th>Permittivity (sec<sup>-1</sup>)</th></tr>

Revision as of 12:27, 5 July 2017

Primary considerations are:

  1. Maximum forces that will be exerted on the fabric (i.e., what tensile, tear and puncture strength ratings are required?);
  2. Load bearing ratio of the underlying native soil (i.e. is the geotextile needed to prevent downward migration of aggregate into the native soil?);
  3. Texture (i.e., grain size distribution) of the overlying fill material; and
  4. Permeability of the native soil
  5. Suitable apparent opening size (AOS) for non-woven fabrics, or percent open area (POA) for woven fabrics, to maintain water flow even with sediment and microbial film build-up;
Recommended criteria for selection of geotextile fabric
Percent media passing 0.075 mm (#200 sieve)Non-woven fabric apparent opening size (AOS, mm)Woven fabric percent open area (POA, %)Permittivity (sec-1)
>85≤ 0.3Not recommended0.1
50 - 85≥ 4
15 - 50≤ 0.60.2
5 - 150.5
≤ 5≥ 10