Revision as of 20:16, 18 August 2017
Before beginning the sizing calculations most of the following parameters must be known or estimated. The exceptions are the depth (d) and Permeable area (P), as only one of these is required to find the other. Note that some of these parameters are limited:
- The maximum total depth will be limited by construction practices i.e. not usually > 2 m.
- The maximum total depth may be limited by the conditions underground e.g. the groundwater or underlying geology/infrastructure.
- The minimum total depth may be limited by the need to support vegetation i.e. not < 0.6 m.
- The area P for a green roofs, absorbent landscapes and permeable paving may be very similar or equal to the catchment area, so that the I/P ratio is close to 1.
- Infiltration trenches, chambers and bioretention cells have a maximum recommended I/P ratio of 20.
Symbol | Units | Parameter |
---|---|---|
D | hrs | Duration of design storm (for MOECC volume based caclulations set to 1) |
i | mm/hr | Intensity of design storm (for MOECC volume based calculations use whole storm depth (link to map)) |
q | mm/hr | Infiltration coefficient, calculated from measured infiltration rate and applied safety factor |
n | - | Porosity, as measured (or default to 0.35) |
I | m2 | Impermeable area i.e. catchment |
d | m | depth of Infiltration facility or BMP |
P | m2 | Permeable area i.e. area of the facility or BMP |
The following equations assume that infiltration occurs primarily through the base of the facility. They may be applied for most shapes and sizes of infiltration facility. For some geometries (e.g. where a particularly deep facility is both possible and desired), it may be preferred to also account for lateral infiltration.
To calculate the required depth, where the area of the facility is constrained:
To calculate the require facility area or footprint where the depth is constrained:
This spreadsheet has been set up to perform either of the above calculations. Download .xlsx calculation tool