{|class="wikitable" | {|class="wikitable" | ||
|+ | |+Specifications for pervious concrete, porous asphalt, and permeable pavers | ||
|- | |- | ||
! | !Material | ||
! | !Specification | ||
! | !Quantity | ||
|- | |- | ||
|'''Pervious Concrete''' | |||
| | |||
|* 28 day compressive strength = 5.5 to 20 MPa | * 28 day compressive strength = 5.5 to 20 MPa | ||
* Void ratio = 14% - 31% | |||
* Permeability = 900 - 21,500 mm/hr | |||
|Thickness will range from 100 mm-150 mm depending on the expected loads | |||
|- | |- | ||
|'''Porous Asphalt''' | |||
|* open-graded asphalt mix with a minimum of 16% air voids | | | ||
* open-graded asphalt mix with a minimum of 16% air voids | |||
* Polymer can be added to provide additional strength to heavy loads | |||
|Thickness will range from 50 mm-100 mm depending on the expected loads | |||
|- | |- | ||
|'''Permeable Pavers''' | |||
|*ASTM No. 8(5 mm dia) crused aggregate is recommended for fill material in the paver openings. | | | ||
*ASTM No. 8(5 mm dia) crused aggregate is recommended for fill material in the paver openings. | |||
*Pavers shall meet the minimum material and standard specification for Precast Concrete Pavers. | |||
*Pigment in concrete pavers shall conform to ASTM C 979 ACI Report No. 212.3R provides guidance on the use of pigments. | |||
*Maximum allowable breakage of product is 5% | |||
| | |||
*For vehicle applications the minimum paver thickness is 80 mm | |||
*For pedestrian applications is 60 mm and Joint widths should be no greater than 15 mm. | |||
|- | |- |
Revision as of 20:32, 16 October 2017
Material | Specification | Quantity |
---|---|---|
Pervious Concrete |
|
Thickness will range from 100 mm-150 mm depending on the expected loads |
Porous Asphalt |
|
Thickness will range from 50 mm-100 mm depending on the expected loads |
Permeable Pavers |
|
|