From LID SWM Planning and Design Guide
Jump to navigation
Jump to search
Specifications for pervious concrete, porous asphalt, and permeable pavers
Material
|
Specification
|
Quantity
|
Pervious concrete
|
- NO4-RG-S7 mix with air entrainment proven to have the best freeze-thaw durability after 300 freeze-thaw cycles.
- 28 day compressive strength = 5.5 to 20 MPa.
- Porosity between 14% to 31%.
- Permeability = 900 to 21,500 mm/hr.
- Proprietary pre-cast slabs meeting required specifications are also available.
|
Thickness will range from 100 mm - 150 mm depending on the expected loads.
|
Porous asphalt
|
- Open-graded asphalt mix with a minimum porosity of 16%.
- Polymers can be added to provide additional strength to heavy loads.
- The University of New Hampshire Stormwater Center has detailed design specifications for porous asphalt.
|
Thickness will range from 50 mm - 100 mm depending on the expected loads.
|
Permeable Interlocking Pavements
|
- Pavers shall meet the minimum material and standard specifications for precast concrete pavers (CSA A231.2 in Canada; ASTM C936 in United States).
- Open space between pavers (i.e. joint space) typically ranges between 5 and 15% of the total surface area.
- ASTM No. 8 (5 mm dia.) crushed aggregate is recommended for fill material in the paver joints (typically HPB).
- For narrow joint pavers, a smaller sized aggregate may be used. Narrow joints are required where pavement must be AODA compliant.
|
- For vehicle applications the minimum paver thickness is 80 mm
- For pedestrian applications the minimum paver thickness is 60 mm and joint widths should be no greater than 15 mm.
|