Line 124: Line 124:
*f<sub>m, min</sub> = minimum infiltration rate (i.e. saturated hydraulic conductivity) of the filter media (m/h), see [[Bioretention: Filter media|Filter media]] for guidance}}<br>
*f<sub>m, min</sub> = minimum infiltration rate (i.e. saturated hydraulic conductivity) of the filter media (m/h), see [[Bioretention: Filter media|Filter media]] for guidance}}<br>
For practices where flow is delivered to the storage reservoir:
For practices where flow is delivered to the storage reservoir:
<math>A_{p}=i\times D\times A_{i}/[(d_{a}\times n) + (f' \times D)]</math>
<math>A_{p}=i\times D\times A_{i}/[(d_{a}\times n') + (f' \times D)]</math>
{{Plainlist|1=Where:
{{Plainlist|1=Where:
*d<sub>a</sub> = Active storage depth (m)
*d<sub>a</sub> = Active storage depth (m)
*n = porosity of storage reservoir aggregate, or effective porosity of void-producing structure system (with underdrain), or effective porosity of surface ponding depth and filter media depth combined (no underdrain design only)
*n' = effective porosity of the active storage fill material(s), (effective porosity of surface ponding depth and filter media depth combined for practices with no underdrain; porosity of storage reservoir aggregate or effective porosity of void-producing structure system for practices with an underdrain)
*f' = design infiltration rate of the underlying native soil (m/h)
*f' = design infiltration rate of the underlying native soil (m/h)
*D = Design storm duration (h)}}<br>
*D = Design storm duration (h)}}<br>