===For full infiltration design, to calculate the total depth of clear stone aggregate layers needed for the water storage reservoir===  
===For full infiltration design, to calculate the total depth of clear stone aggregate layers needed for the water storage reservoir===  
The equation for the maximum depth of the stone reservoir (''d<sub>r, max</sub>'', m) is as follows:  
The equation for the maximum depth of the stone reservoir (''d<sub>r, max</sub>'', m) is as follows:  
<math>d_{r, max}=\frac{(RVC_{T}\times R) + RVC_{T} - (f'\times D)}{n}</math>


<math>d_{r, max}=\frac{(RVC_{T}\times A_{p}) + (RVC_{T}\times A_{i}\times C) - (f'\times D\times A_{p})}{n}</math>
<math>d_{r, max}=\frac{(RVC_{T}\times A_{p}) + (RVC_{T}\times A_{i}\times C) - (f'\times D\times A_{p})}{n}</math>