| [[File:Subsurface draw outlet.PNG|500px|thumb|Schematic of a reverse sloped subsurface draw outlet to help ensure cooler outflows occur from stormwater ponds (MOE, 2003).<ref>Ministry of the Environment. 2003. Stormwater Management Planning and Design Manual. March, 2003. ISBN 0-7794-2969-9. PIBS 4329e. https://dr6j45jk9xcmk.cloudfront.net/documents/1757/195-stormwater-planning-and-design-en.pdf</ref>]] | | [[File:Subsurface draw outlet.PNG|500px|thumb|Schematic of a reverse sloped subsurface draw outlet to help ensure cooler outflows occur from stormwater ponds (MOE, 2003).<ref>Ministry of the Environment. 2003. Stormwater Management Planning and Design Manual. March, 2003. ISBN 0-7794-2969-9. PIBS 4329e. https://dr6j45jk9xcmk.cloudfront.net/documents/1757/195-stormwater-planning-and-design-en.pdf</ref>]] |
|
| |
|
| There are several opportunities to mitigate thermal impacts both within the pond itself and/or implemented within the upstream drainage area (and the lands surrounding) of the pond. Options shown in past studies to provide appreciable thermal mitigation benefits include (Van Seters and Dougherty, 2019) | | There are several opportunities to mitigate thermal impacts both within the pond itself and/or implemented within the upstream drainage area (and the lands surrounding) of the pond. Options shown in past studies to provide appreciable thermal mitigation benefits include (Van Seters and Dougherty, 2019)<ref>Van Seters, T., Graham, C., Dougherty, J., Jacob-Okor, C., and David, Y. 2019. Data Synthesis and Design Considerations for Stormwater Thermal Mitigation Measures. Sustainable Technologies Evaluation Program. Ontario. https://sustainabletechnologies.ca/app/uploads/2019/04/Thermal-Synthesis-Final.pdf</ref>]] |
|
| |
|
| ===Subsurface Draw Outlets=== | | ===Subsurface Draw Outlets=== |
Line 91: |
Line 91: |
| ====Design Considerations==== | | ====Design Considerations==== |
| *Optimal 8 hour duration for night time release outlets was found to be between 3 AM and 10 AM inclusive based on data from 4 ponds | | *Optimal 8 hour duration for night time release outlets was found to be between 3 AM and 10 AM inclusive based on data from 4 ponds |
| *Optimal 4 hour duration release times were found to be between 6 and 9 AM inclusive (Van Seters and Dougherty, 2019). | | *Optimal 4 hour duration release times were found to be between 6 and 9 AM inclusive (Van Seters and Dougherty, 2019)<ref>Van Seters, T., Graham, C., Dougherty, J., Jacob-Okor, C., and David, Y. 2019. Data Synthesis and Design Considerations for Stormwater Thermal Mitigation Measures. Sustainable Technologies Evaluation Program. Ontario. https://sustainabletechnologies.ca/app/uploads/2019/04/Thermal-Synthesis-Final.pdf</ref>]]. |
| *Robust automation technology is critical to avoid excessive repairs and down time. | | *Robust automation technology is critical to avoid excessive repairs and down time. |
| *Electrical supply and back-up power are typically needed at the outlet to reduce operation and maintenance requirements | | *Electrical supply and back-up power are typically needed at the outlet to reduce operation and maintenance requirements |