Changes

Jump to navigation Jump to search
Line 2: Line 2:
[[File:Cistern Size.png|thumb|Schematic diagram of the inputs and outputs to a rainwater harvesting cistern]]
[[File:Cistern Size.png|thumb|Schematic diagram of the inputs and outputs to a rainwater harvesting cistern]]
===Simple===
===Simple===
{{plainlist|
*Five percent of the average annual yield can be estimated:
*<strong>Y<sub>0.05</sub>&#61;  A × C<sub>vol, A</sub> × R<sub>a</sub> × e × 0.05</strong>
*Y<sub>0.05</sub> &#61;  Five percent of the average annual yield (L)
*A &#61;  The catchment area (m<sup>2</sup>)
*C<sub>vol, A</sub> &#61;  The annual runoff coefficient for the catchment
*R<sub>a</sub> &#61;  The average annual rainfall depth (mm)
*e &#61; The efficiency of the pre-storage filter
}}
Filter efficiency (e) can be reasonably estimated as 0.9 pending manufacturer’s information.
Filter efficiency (e) can be reasonably estimated as 0.9 pending manufacturer’s information.
In a study of three sites in Ontario, STEP found the annual C<sub>vol, A</sub> of the rooftops to be around 0.8 [http://www.sustainabletechnologies.ca/wp/home/urban-runoff-green-infrastructure/low-impact-development/rainwater-harvesting/performance-evaluation-of-rainwater-harvesting-systems-toronto-ontario/]. This figure includes losses to evaporation, snow being blown off the roof, and number of overflow events.<br>
In a study of three sites in Ontario, STEP found the annual C<sub>vol, A</sub> of the rooftops to be around 0.8 [http://www.sustainabletechnologies.ca/wp/home/urban-runoff-green-infrastructure/low-impact-development/rainwater-harvesting/performance-evaluation-of-rainwater-harvesting-systems-toronto-ontario/]. This figure includes losses to evaporation, snow being blown off the roof, and number of overflow events.<br>