Bioretention: TTT
Revision as of 00:13, 6 September 2017 by Jenny Hill (talk | contribs) (Created page with "{| class="prettytable" |- | colspan="2" |<center>'''Surface'''</center> |- |Berm height (mm) |Sometimes referred to as the bowl depth |- |Surface roughness (Manning’s n) |Lo...")
Berm height (mm) | Sometimes referred to as the bowl depth |
Surface roughness (Manning’s n) | Lower numbers indicate less surface obstruction and result in faster flow
Suggested ranges:
|
Surface slope (%) | If the slope > 3% , a series of [[Checkdams]] or weirs should be included in the design. |
Thickness (mm) | Depth of filter media |
Porosity (fraction) | Suggest range 0.35 – 0.4 unless otherwise tested |
Field capacity (fraction) | Suggested range 0.10 - 0.12 <ref name = SWMM/> |
Wilting point (fraction) | Suggested value 0.03 <ref name = SWMM/> |
Conductivity (mm/hr) | Suggested range 25 – 250 mm/hr |
Conductivity slope | Suggested value 45 <ref name = SWMM/> |
Suction head (mm) | Suggested range 50 - 60 <ref name = SWMM/> |
Thickness (mm) | Depth of storage aggregates layer |
Void ratio | Suggest range 0.35 – 0.4 unless otherwise tested |
Seepage rate (mm/hr) | Infiltration rate of native soil |
Clogging factor | ? |
Design drawdown time (hrs) | Recommend 48 hours? |
Flow coefficient | Suggested value 1 |
Flow exponent | Suggested value 1 |
Offset height | This is the height from the base of the cell to the height at which the drain discharges. In some designs this may be the height of the perforated pipe within the storage layer [[Bioretention: Partial infiltration]]. In other designs this height is adjusted by creating an upturn in the discharge pipe. [[Bioretention: Internal storage]] |