Permeable pavements: Climate
Revision as of 00:49, 14 November 2017 by Jenny Hill (talk | contribs)
Pervious concrete
Concerns over the resistance to the freeze-thaw cycle have limited the use of pervious concrete in cold weather environments.[1]
The rate of freezing in most applications is dictated by the local climate. Entrained air may help protect the paste like in normal concrete.Cite error: Closing </ref>
missing for <ref>
tag
Avoiding saturation during the freeze cycle is the key to the longevity of the concrete.[2] Related, having a well prepared 8 to 24 inch (200 to 600 mm) sub-base and drainage will reduce the possibility of freeze-thaw damage.[2]
- ↑ Vernon R. Schaefer, Keijin Wang, Muhammad T. Suleiman, John T. Kevern, Mix Design Development for Pervious Concrete in Cold Weather Climates, Iowa State University, Ames, IA, 2006 National Concrete Pavement Technology Center. Report No. 2006-01.mix_design_pervious.pdf
- ↑ 2.0 2.1 Pervious Concrete and Freeze-Thaw http://www.cement.org/tech/Pervious_print.html Concrete Technology E-Newsletter PCA 30 September 2012