Line 137: Line 137:
*f' = Design infiltration rate of the underlying native soil (m/h)
*f' = Design infiltration rate of the underlying native soil (m/h)
*D= Duration of design storm (h)<br>
*D= Duration of design storm (h)<br>
If A<sub>r</sub> is greater than A<sub>p</sub>, calculate the design infiltration water storage depth, d<sub>i</sub>', required to capture the infiltration volume target for the design storm:
If A<sub>r</sub> is greater than A<sub>p</sub>, use the value for A<sub>r</sub> as the required footprint area of the practice.  
<math> d_{i}' = (V_{i}/A_{p})- (f'\times D)</math>
{{Plainlist|1=Where:
*V<sub>i</sub> = Infiltration volume target for the design storm event (m<sup>3</sup>)
*A<sub>p</sub> = Surface area of the practice (m<sup>2</sup>), see equations above to calculate for designs that deliver water to a surface ponding area vs. directly to storage reservoir.
*f' = Design infiltration rate of the underlying native soil (m/h)
*D= Duration of design storm (h)<br>
<br>
<br>
*Step 9: Calculate the required storage reservoir depth, d<sub>r</sub> (m):
*Step 9: Calculate the required storage reservoir depth, d<sub>r</sub> (m):