Flow through an orifice

From LID SWM Planning and Design Guide
Revision as of 22:37, 20 November 2018 by Jenny Hill (talk | contribs)
Jump to navigation Jump to search

Orifices are simply holes which restrict the flow of water. They may be used at the bottom end of an LID practice to add some flow control.

Failed to parse (MathML with SVG or PNG fallback (recommended for modern browsers and accessibility tools): Invalid response ("Math extension cannot connect to Restbase.") from server "https://wikimedia.org/api/rest_v1/":): {\displaystyle Q= B\times C_{d}\times A_{o}\sqrt{2\cdot g\cdot h}}

Where:

  • L is the length of perforated pipe (m)
  • B is the clogging factor (between 0.5 (for matured installation) and 1 (for a new perfectly performing BMP)),
  • Cd is the coefficient of discharge (usually 0.61 for a plate, or 0.8 for a pipe),
  • Ao is the area of the orifice (m2/m),
  • g is acceleration due to gravity = 9.81 m/s2, and
  • h is the head of water over the centre of the orifice.

See also[edit]