To calculate the time (''t'') to fully drain the facility assuming three-dimensional drainage:  
To calculate the time (''t'') to fully drain the facility assuming three-dimensional drainage:  
<math>t=\frac{n\times A_{r}}{f'/times x}ln\left [ \frac{\left (d+ \frac{A_{r}}{x} \right )}{\left(\frac{A_{r}}{x}\right)}\right]</math>
<math>t=\frac{n\times A_{r}}{f'\times x}ln\left [ \frac{\left (d+ \frac{A_{r}}{x} \right )}{\left(\frac{A_{r}}{x}\right)}\right]</math>
Where "ln" means natural logarithm of the term in square brackets <br>
Where "ln" means natural logarithm of the term in square brackets <br>
Adapted from CIRIA, The SUDS Manual C753 (2015).
Adapted from CIRIA, The SUDS Manual C753 (2015).