Changes

Jump to navigation Jump to search
no edit summary
Line 2: Line 2:
File:Kortright trench update.png|thumb|600 px|This infiltration trench features an inlet composed of [[geotextile| filter fabric]] and decorative [[stone| river stone]], which provides some [[pretreatment]] and can easily be removed and replaced as part of routine sediment removal maintenance. For more details click [https://sustainabletechnologies.ca/app/uploads/2016/08/BioVSTrench_TechBrief__July2015.pdf here.] <span style="color:red">''A note: The following is an "image map", feel free to explore the image with your cursor and click on highlighted labels that appear to take you to corresponding pages on the Wiki.''</span>
File:Kortright trench update.png|thumb|600 px|This infiltration trench features an inlet composed of [[geotextile| filter fabric]] and decorative [[stone| river stone]], which provides some [[pretreatment]] and can easily be removed and replaced as part of routine sediment removal maintenance. For more details click [https://sustainabletechnologies.ca/app/uploads/2016/08/BioVSTrench_TechBrief__July2015.pdf here.] <span style="color:red">''A note: The following is an "image map", feel free to explore the image with your cursor and click on highlighted labels that appear to take you to corresponding pages on the Wiki.''</span>
   
   
rect 1061 1333 1388 1631 [[Curb Cuts|Concrete Curb]]
rect 1061 1333 1388 1631 [[Curb cuts|Concrete Curb]]
rect 2211 1339 2527 1640 [[Curb Cuts|Concrete Curb]]  
rect 2211 1339 2527 1640 [[Curb cuts|Concrete Curb]]  
rect 1400 1366 2182 1634 [[Stone|River Rock]]     
rect 1400 1366 2182 1634 [[Stone|River Rock]]     
rect 1595 1091 1946 1186 [[Geotextiles|Geotextile OPSS 1860 Approved Fabric]]   
rect 1595 1091 1946 1186 [[Geotextiles|Geotextile OPSS 1860 Approved Fabric]]   
rect 1344 847 2144 962 [[Permeable Pavements|Permeable Paver]]   
rect 1344 847 2144 962 [[Permeable pavements|Permeable Paver]]   
rect 2536 1336 3330 1381 [[Permeable Pavements|Permeable Paver]]  
rect 2536 1336 3330 1381 [[Permeable pavements|Permeable Paver]]  
rect 1185 1041 2017 971 [[Choker layer|High performance bedding]]
rect 1185 1041 2017 971 [[Choker layer|High performance bedding]]
rect 1075 1637 1394 1788 [[OPSS aggregates|Crushed Limestone]]
rect 1075 1637 1394 1788 [[OPSS aggregates|Crushed Limestone]]
Line 15: Line 15:
rect 2542 1443 3330 1702 [[OPSS aggregates|Well-graded granular A Material (OPSS 1010)]]
rect 2542 1443 3330 1702 [[OPSS aggregates|Well-graded granular A Material (OPSS 1010)]]
circle 2858 2125 69 [[Underdrains|Underdrain]]
circle 2858 2125 69 [[Underdrains|Underdrain]]
rect 1403 1968 2182 1649 [[Reservoir Aggregate|Clearstone]]  
rect 1403 1968 2182 1649 [[Reservoir aggregate|Clearstone]]  
rect 1394 1971 3333 2286 [[Reservoir Aggregate|Clearstone]]  
rect 1394 1971 3333 2286 [[Reservoir aggregate|Clearstone]]  
rect 1 1339 1061 2470 [[Soil Groups|Native Soil]]  
rect 1 1339 1061 2470 [[Soil groups|Native Soil]]  
        
        
</imagemap>
</imagemap>
Line 64: Line 64:

===Water Table===
===Water Table===
Maintaining a separation of one (1) metre between the elevations of the base of the practice and the seasonally high water table, or top of bedrock is recommended. Lesser or greater values may be considered based on groundwater mounding analysis. See STEP LID Planning and Design Guide wiki page, [[Groundwater]] for further guidance and spreadsheet tool.
Maintaining a separation of one (1) metre between the elevations of the base of the practice and the seasonally high water table, or top of bedrock is recommended. Lesser or greater values may be considered based on groundwater mounding analysis. See [[Groundwater]] for further guidance and spreadsheet tool.


===Pollution Hot Spot Runoff===
===Pollution Hot Spot Runoff===
Line 72: Line 72:
Designers should consult local utility design guidance for the horizontal and vertical clearances required between storm drains.
Designers should consult local utility design guidance for the horizontal and vertical clearances required between storm drains.


===Karst===
===[[Karst]]===
Infiltration trenches, chambers and soakaways are not suitable in areas of known or implied karst topography.  
Infiltration trenches, chambers and soakaways are not suitable in areas of known or implied karst topography.


===Setback from Buildings===
===Setback from Buildings===
Line 179: Line 179:
|}
|}


==Performance==
===Water Quality===
Take a look at the [[Infiltration Trench: Performance]] page by clicking below for further details about STEPs collected performance results for Infiltratio ntrench practices located within TRCA's, CVC's and LSRCA's watersheds: <br>
</br>
{{Clickable button|[[File:TP effluent comparison.PNG|150 px|link=https://wikidev.sustainabletechnologies.ca/wiki/Infiltration_Trench:_Performance]]}}


==Materials==
==Materials==

Navigation menu