Line 1: |
Line 1: |
| [[File:Sizing flow-through planter.jpg|thumb|A flow-through planter comprises a ponding zone, mulch layer, filter media for planting, and a supporting gravel drainage layer]] | | [[File:Sizing flow-through planter.jpg|thumb|A flow-through planter comprises a ponding zone, mulch layer, filter media for planting, and a supporting gravel drainage layer]] |
| This article is specific to [[Flow-through stormwater planters]], vegetated systems that do not infiltrate water to the native soil. <br> | | This article is specific to flow-through [[Stormwater planters|stormwater planters]], vegetated systems that do not infiltrate water to the native soil. <br> |
| If you are designing a planted system which does infiltrate water, see advice on [[Bioretention: Sizing]]. | | If you are designing a planted system which does infiltrate water, see advice on [[Bioretention: Sizing]]. |
| {{TOClimit|2}}
| | |
| The dimensions of a stormwater planter are largely predetermined according to the function of the component. As they do not contain a storage reservoir the planters rely more upon careful selection of materials. Both the filter media and the perforations of the pipe play critical roles for flow control. | | The dimensions of a stormwater planter are largely predetermined according to the function of the component. As they do not contain a storage reservoir the planters rely more upon careful selection of materials. Both the filter media and the perforations of the [[Pipe| pipe]] play critical roles for flow control. |
|
| |
|
| {| class="wikitable" | | {| class="wikitable" |
Line 9: |
Line 9: |
| ! Component | | ! Component |
| ! Recommended depth (with underdrain pipe) | | ! Recommended depth (with underdrain pipe) |
| ! Typical void ratio (''V<sub>R</sub>'') | | ! Typical porosity (''n'') |
| |- | | |- |
| | Ponding (''d<sub>p</sub>'') | | | Ponding (''d<sub>p</sub>'') |
| | ≥ 300 mm | | | 150 to 450 mm |
| | 1 | | | 1 |
| |- | | |- |
Line 19: |
Line 19: |
| | | | | |
| * 0.7 for wood based | | * 0.7 for wood based |
| * 0.4 for aggregate | | * 0.4 for stone |
| |- | | |- |
| | [[Bioretention: Filter media|filter media]] (''d<sub>m</sub>'') | | | [[Bioretention: Filter media|Filter media]] (''d<sub>m</sub>'') |
| | | | | |
| * 300 mm to support turf grass (and accept only rainwater/roof runoff) | | * 300 mm to support turf grass (and accept only rainwater/roof runoff) |
| * 600 mm to support flowering [[perennials]] and decorative [[grasses]] | | * 600 mm to support shrubs, flowering [[perennials]] and decorative [[grasses]] |
| * 1000 mm to support [[trees]] | | * 1000 mm to support [[trees]] |
| | 0.3 | | | |
| | * 0.35 for Blend A - Drainage rate priority; |
| | * 0.4 for Blend B - Water quality treatment priority |
| |- | | |- |
| | Pipe diameter reservoir | | | Pipe diameter reservoir |
| | Is equal to underdrain pipe diameter | | | Is equal to underdrain [[pipe]] diameter |
| | 0.4 | | | 0.4 |
| |- | | |- |
| | Pipe bedding (''d<sub>b</sub>'') | | | [[Choker course|Pipe bedding]] (''d<sub>b</sub>'') |
| | 50 mm (although commonly omitted altogether). | | | 50 mm (although commonly omitted altogether). |
| | 0.4 | | | 0.4 |
| |} | | |} |
|
| |
|
| |
| ==Calculate the maximum overall depth==
| |