Changes

Jump to navigation Jump to search
no edit summary
Line 1: Line 1:
[[File:Sizing flow-through planter.jpg|thumb|A flow-through planter comprises a ponding zone, mulch layer, filter media for planting, and a supporting gravel drainage layer]]
[[File:Sizing flow-through planter.jpg|thumb|A flow-through planter comprises a ponding zone, mulch layer, filter media for planting, and a supporting gravel drainage layer]]
This article is specific to [[Flow-through stormwater planters]], vegetated systems that do not infiltrate water to the native soil. <br>
This article is specific to flow-through [[Stormwater planters|stormwater planters]], vegetated systems that do not infiltrate water to the native soil. <br>
If you are designing a planted system which does infiltrate water, see advice on [[Bioretention: Sizing]].
If you are designing a planted system which does infiltrate water, see advice on [[Bioretention: Sizing]].
{{TOClimit|2}}
 
The dimensions of a stormwater planter are largely predetermined according to the function of the component. As they do not contain a storage reservoir the planters rely more upon careful selection of materials. Both the filter media and the perforations of the pipe play critical roles for flow control.   
The dimensions of a stormwater planter are largely predetermined according to the function of the component. As they do not contain a storage reservoir the planters rely more upon careful selection of materials. Both the filter media and the perforations of the [[Pipe| pipe]] play critical roles for flow control.   


{| class="wikitable"
{| class="wikitable"
Line 9: Line 9:
! Component
! Component
! Recommended depth (with underdrain pipe)
! Recommended depth (with underdrain pipe)
! Typical void ratio (''V<sub>R</sub>'')
! Typical porosity (''n'')
|-
|-
| Ponding (''d<sub>p</sub>'')
| Ponding (''d<sub>p</sub>'')
| ≥ 300 mm
| 150 to 450 mm
| 1
| 1
|-
|-
Line 19: Line 19:
|  
|  
* 0.7 for wood based
* 0.7 for wood based
* 0.4 for aggregate
* 0.4 for stone
|-
|-
| [[Bioretention: Filter media|filter media]] (''d<sub>m</sub>'')
| [[Bioretention: Filter media|Filter media]] (''d<sub>m</sub>'')
|  
|  
* 300 mm to support turf grass (and accept only rainwater/roof runoff)
* 300 mm to support turf grass (and accept only rainwater/roof runoff)
* 600 mm to support flowering [[perennials]] and decorative [[grasses]]
* 600 mm to support shrubs, flowering [[perennials]] and decorative [[grasses]]
* 1000 mm to support [[trees]]
* 1000 mm to support [[trees]]
| 0.3
|
* 0.35 for Blend A - Drainage rate priority;
* 0.4 for Blend B - Water quality treatment priority
|-
|-
| Pipe diameter reservoir
| Pipe diameter reservoir
| Is equal to underdrain pipe diameter
| Is equal to underdrain [[pipe]] diameter
| 0.4  
| 0.4  
|-
|-
| Pipe bedding (''d<sub>b</sub>'')
| [[Choker course|Pipe bedding]] (''d<sub>b</sub>'')
| 50 mm (although commonly omitted altogether).  
| 50 mm (although commonly omitted altogether).  
| 0.4
| 0.4
|}
|}