''q'' is the inflow volume expressed as a depth over the entire surface (m)
''q'' is the inflow volume expressed as a depth over the entire surface (m)
===Example===
===Example===
[[File:Drain spacing.jpg|thumb|The yellow box represents the recommended hydraulic conductivity of bioretention filter media]]
During a 25 mm storm event, a bioretention cell receives concentrated flow from a catchment 20 times larger than its own footprint (25 x 20 = 500 mm = 0.5 m).  
During a 25 mm storm event, a bioretention cell receives concentrated flow from a catchment 20 times larger than its own footprint (25 x 20 = 500 mm = 0.5 m).  
The bioretention cell comprises 0.6 m filter media (K = 2.4 m/day), laid over 0.6 m clear, coarse reservoir gravel. The pipes are laid within the reservoir, 0.9 m below the surface.  
The bioretention cell comprises 0.6 m filter media (K = 2.4 m/day), laid over 0.6 m clear, coarse reservoir gravel. The pipes are laid within the reservoir, 0.9 m below the surface.  