Line 21: | Line 21: | ||
;N :Number of days in the month | ;N :Number of days in the month | ||
; | ;x :Perimeter of infiltration practice or swale x-section (m) | ||
; | ;f':Design infiltration rate (length per time, usually mm/hr) after application of safety correction factor (SCF) | ||
;Q<sub>p</sub> :Peak flow in units of volume per time (e.g. m<sup>3</sup>/s) | ;Q<sub>p</sub> :Peak flow in units of volume per time (e.g. m<sup>3</sup>/s) | ||
Line 35: | Line 33: | ||
;R<sub>b</sub> :Rise of compensation gradient for an enhanced swale (length, usually m) | ;R<sub>b</sub> :Rise of compensation gradient for an enhanced swale (length, usually m) | ||
;RVC<sub>T</sub> :Runoff volume control target (as outlined by | ;RVC<sub>T</sub> :Runoff volume control target (as outlined by MECP, units are mm) | ||
;S<sub>0</sub> :Longitudinal slope (m/m, i.e. dimensionless) | ;S<sub>0</sub> :Longitudinal slope (m/m, i.e. dimensionless) | ||
Line 51: | Line 49: | ||
;V :Volume (usually in m<sup>3</sup>) | ;V :Volume (usually in m<sup>3</sup>) | ||
; | ;n :Porosity, applies to aggregate and other void-forming materials, filter media and native soils (unit is vol/vol, so dimensionless) | ||
;y :Depth of water (L, usually m or sometimes mm) | ;y :Depth of water (L, usually m or sometimes mm) |
Revision as of 16:40, 22 April 2020
- Ac
- Area of the catchment, whole contributing drainage area (usually in m2).
- Ap
- Area of the practice e.g. footprint area of a bioretention cell (usually in m2)
- d
- Depth e.g. of an infiltration practice (units of length, usually mm or m)
- f
- Infiltration rate (usually mm/hr)
- h
- height (units of length)
- i
- Thornthwaite monthly heat index (-)
- I
- Thornthwaite annual heat index (-)
- L
- Length, e.g. of a reach, channel or swale (usually in m)
- m
- run of side slopes in channel cross sections (length, but usually expressed as a ratio in relation to rise. e.g. side slopes = 1:3, so m = 3)
- n
- Manning's coefficient (unitless) Note: for clarity porosity is being expressed as 'void ratio' and sharing the notation VR
- N
- Number of days in the month
- x
- Perimeter of infiltration practice or swale x-section (m)
- f'
- Design infiltration rate (length per time, usually mm/hr) after application of safety correction factor (SCF)
- Qp
- Peak flow in units of volume per time (e.g. m3/s)
- R
- Ratio of catchment (Ac) to the practice footprint area (Ap). syn. I/P ratio. For green roofs (and often permeable paving systems) this will be 1:1. In bioretention it may be 15 or 20 to 1.
- Ra
- Existing rise of swale gradient (length, usually m)
- Rb
- Rise of compensation gradient for an enhanced swale (length, usually m)
- RVCT
- Runoff volume control target (as outlined by MECP, units are mm)
- S0
- Longitudinal slope (m/m, i.e. dimensionless)
- ST
- Storage (m3)
- Sx
- Cross slope (m/m, i.e. dimensionless)
- SCF
- Safety correction factor (dimensionless)
- t
- time (usually in hrs)
- T
- Temperature (°C)
- V
- Volume (usually in m3)
- n
- Porosity, applies to aggregate and other void-forming materials, filter media and native soils (unit is vol/vol, so dimensionless)
- y
- Depth of water (L, usually m or sometimes mm)