Difference between revisions of "Bioretention: Sizing and modeling"

From LID SWM Planning and Design Guide
Jump to navigation Jump to search
 
(142 intermediate revisions by 2 users not shown)
Line 1: Line 1:
Before beginning the sizing calculations most of the following parameters must be known or estimated.  
This article describes recommended design approaches when available space for the practice is constrained.<br>
The exceptions are the depth (''d'') and Permeable area (''P''), as only one of these is required to find the other.  
<br>
Note that some of these parameters are limited:
Before beginning the sizing calculations certain parameters must be known or estimated. See [[Bioretention: Sizing]] for parameter descriptions and conceptual diagram illustrating key components of bioretention practices. Note that some of these parameters are limited:
#The ''maximum'' total depth will be limited by construction practices i.e. not usually > 2 m.
#The ''maximum'' total depth will be limited by construction practices i.e. not usually > 2 m.
#The ''maximum'' total depth may be limited by the [[Infiltration| conditions underground]] e.g. the groundwater or underlying geology/infrastructure.
#The ''maximum'' total depth may be limited by the [[Infiltration| conditions underground]] e.g. the groundwater or underlying geology/infrastructure.
#The minimum total depth may be limited by the need to support vegetation i.e. not < 0.6 m.
#The minimum total depth will be limited by the need to support vegetation (e.g not less than 0.6 m to support deep rooting perennials and shrubs).
#[[Green roofs]], [[absorbent landscapes]] and [[permeable paving]] often receive very little flow from other surfaces, so that the I/P ratio is close to 1.
#[[Bioretention]] has a maximum recommended catchment impervious area to practice permeable (footprint) area ratio, R (or I/P ratio) of 20.
#[[Infiltration trenches]], [[Infiltration chambers| chambers]] and [[bioretention cells]] have a maximum recommended I/P ratio of 20.
 
 


==Size a bioretention cell receiving flows directly to the storage reservoir for a constrained depth==
If there is a constraint to the depth (''d<sub>T</sub>'') of the practice, calculate the required storage reservoir footprint area (''A<sub>r</sub>''), as:
<math>A_{r}=\frac{i\times D\times A_i}{(d_{r}\times n')+(f'\times D)}</math>
{{Plainlist|1=Where:
{{Plainlist|1=Where:
*''D'' = Duration of design storm in hrs
*''A<sub>r</sub>'' = Area of the infiltration practice storage reservoir (m<sup>2</sup>)
*''i'' = Intensity of design storm in mm/hr
*''A<sub>i</sub>'' = Catchment impervious area (m<sup>2</sup>)
*''q'' = Infiltration rate of underlying soil in mm/hr
*''D'' = Duration of design storm (h)
*''SF'' = Safety factor
*''i'' = Intensity of design storm (mm/h)
*''V<sub>R</sub>'' = Void ratio (porosity), as measured (or default to 0.35 for all aggregates)*
*''f''' = [[design infiltration rate]] (m/h)
*''R'' = Ratio of catchment area (''A<sub>c</sub>'') to BMP footprint area (A<sub>p</sub>) syn. I/P ratio. 
*''n''' = Effective porosity of the fill material in the storage reservoir of the practice
*''A<sub>p</sub>'' = Area of the infiltration practice in m<sup>2</sup>
*''d<sub>r</sub>'' = Storage reservoir depth, based on depth available between the elevation of the invert of the underdrain perforated pipe and one (1) metre above the seasonally high water table or top of bedrock  (m) or other value determined to be suitable through groundwater mounding analysis.}}<br>
*''A<sub>c</sub>'' = Catchment area in m<sup>2</sup>
If R is greater than 20, consider decreasing catchment impervious area (A<sub>i</sub>) by draining less area to the practice.
*''d'' = Depth of infiltration practice in m.}}


*Note: For systems that have significant storage in clear open chambers, an effective porosity value (''V<sub>R</sub><nowiki>'</nowiki>'') may be estimated for the whole installation and used in the calculations below. Effective porosity will vary according to the geometry of the storage chambers, so advice should be sought from product manufacturers. Permit applications should include the basis for ''V<sub>R</sub><nowiki>'</nowiki>'' estimates.
==Size a bioretention cell where drainage area and practice area are fixed==
If the land area is limited, determine the I/P ratio, which is the ratio of catchment impervious area (A<sub>i</sub>) to practice pervious footprint area (A<sub>p</sub>):
:<math>R=\frac{A_{i}}{A_{p}}</math>


{{Plainlist|1= Where:
*''R'' = Ratio of catchment impervious area to practice pervious footprint area, also referred to as I/P ratio
*''A<sub>p</sub>'' = Practice pervious footprint area in m<sup>2</sup>
*''A<sub>i</sub>'' = Catchment impervious area in m<sup>2</sup>}}


The following equations assume that infiltration occurs primarily through the base of the facility.
Then calculate the required storage reservoir depth (''d<sub>r</sub>''), as:
They may be easily applied for any shape and size of infiltration facility, in which the reservoir storage is mostly in an aggregate. 
<math>d_{r}=\frac{D \left[ (R\times i)-f'\right]}{n'}</math>


To calculate the required depth, where the area of the facility is constrained:
{{Plainlist|1=Where:
<math>d=\frac{D\left[Ri-\left ( \frac{q}{SCF} \right ) \right]}{V_{R}}</math>
*''D'' = Duration of design storm (h)
*''i'' = Intensity of design storm (m/h)
*''f''' = Design infiltration rate (m/h)
*''n''' = Effective porosity of the storage reservoir fill material}}
These equations assume that infiltration occurs primarily through the base of the facility.<br>
<br>
This spreadsheet tool has been set up to perform all of the infiltration practice sizing calculations shown above.<br>
{{Clickable button|[[Media:Infiltration Sizing 20200525 locked.xlsx|Download the infiltration practice sizing tool]]}}


To calculate the require facility area or footprint where the depth is constrained:
==Calculate drawdown time==
<math>A_{p}=\frac{IiD}{V_{R}d+\left ( \frac{q}{SCF} \right )D}</math>
[[file:Hydraulic radius.png|thumb|Two footprint areas of 9 m<sup>2</sup>.<br>
Perimeter = 12 m (left) Perimeter = 20 m (right)]]


This spreadsheet tool has been set up to perform either of the above calculations.<br>
{{Clickable button|[[Media:Darcy drainage_20200528_locked.xlsx|Download the Darcy drainage time calculator tool]]}}
<strong>[[Media:Infiltration Sizing.xlsx|Download .xlsx calculation tool]]</strong>


To calculate the time (''t'') to fully drain the facility:  
In some situations, it may be possible to reduce the size of the bioretention required, by accounting for rapid drainage. Typically, this is only worth exploring over sandy soils with rapid infiltration.
<math>t=\frac{nd}{q}</math>
Note that narrow, linear bioretention features drain faster than round or blocky footprint geometries.
 
*Begin the drainage time calculation by dividing the storage reservoir area of the practice (''A<sub>r</sub>'') by the perimeter (''x'').
==Accounting for lateral infiltration==
*Use the following equation to estimate the time (''t'') to fully drain the facility:  
[[file:Hydraulic radius.png|thumb|Three footprint areas of 9 m<sup>2</sup>.<br>
:<math>t=\frac{nA_{r}}{f'x}ln\left [ \frac{\left (d_{r}+ \frac{A_{r}}{x} \right )}{\left(\frac{A_{r}}{x}\right)}\right]</math>
From left to right x = 12 m, x = 14 m, and x = 16 m]]
{{Plainlist|1=Where:
For some geometries (e.g. particularly deep facilities or linear facilities), it may be preferred to also account for lateral infiltration.
*''n'' is the porosity of the storage reservoir fill material
The 3 dimensional equations make use of the hydraulic radius (''P''/''x''), where ''x'' is the perimeter (m) of the facility. <br>
*''A<sub>r</sub>'' is the storage reservoir footprint area (m<sup>2</sup>),
Maximizing the perimeter of the facility directs designers towards longer, linear shapes such as [[infiltration trenches]] and [[bioswales]]. 
*''f''' is the design infiltration rate of the native soil (mm/h),  
 
*''x'' is the perimeter of the practice (m), and
To calculate the required depth:
*''d<sub>r</sub>'' is the depth of the storage reservoir (m).}}
:<math>d=a[e^{\left ( -bD \right )} -1]</math>
Where
<math>a=\frac{P}{x}-\frac{i I}{P q}</math>
and
<math>b=\frac{xq}{nP}</math>
 
The rearrangement to calculate the required footprint area of the facility for a given depth is not available at this time. Elegant submissions are invited.  


To calculate the time (''t'') to fully drain the facility:
This 3 dimensional equation makes use of the hydraulic radius (''A<sub>r</sub>''/''x''), where ''x'' is the perimeter (m) of the facility. <br>
<math>t=\frac{nP}{qx}ln\left [ \frac{\left (d+ \frac{P}{x} \right )}{\left(\frac{P}{x}\right)}\right]</math>
Maximizing the perimeter of the facility directs designers towards longer, linear shapes such as [[bioswales]]


[[category: modeling]]
[[category: modeling]]
[[category: infiltration]]
[[category: infiltration]]

Latest revision as of 21:02, 2 June 2020

This article describes recommended design approaches when available space for the practice is constrained.

Before beginning the sizing calculations certain parameters must be known or estimated. See Bioretention: Sizing for parameter descriptions and conceptual diagram illustrating key components of bioretention practices. Note that some of these parameters are limited:

  1. The maximum total depth will be limited by construction practices i.e. not usually > 2 m.
  2. The maximum total depth may be limited by the conditions underground e.g. the groundwater or underlying geology/infrastructure.
  3. The minimum total depth will be limited by the need to support vegetation (e.g not less than 0.6 m to support deep rooting perennials and shrubs).
  4. Bioretention has a maximum recommended catchment impervious area to practice permeable (footprint) area ratio, R (or I/P ratio) of 20.

Size a bioretention cell receiving flows directly to the storage reservoir for a constrained depth[edit]

If there is a constraint to the depth (dT) of the practice, calculate the required storage reservoir footprint area (Ar), as:

Where:

  • Ar = Area of the infiltration practice storage reservoir (m2)
  • Ai = Catchment impervious area (m2)
  • D = Duration of design storm (h)
  • i = Intensity of design storm (mm/h)
  • f' = design infiltration rate (m/h)
  • n' = Effective porosity of the fill material in the storage reservoir of the practice
  • dr = Storage reservoir depth, based on depth available between the elevation of the invert of the underdrain perforated pipe and one (1) metre above the seasonally high water table or top of bedrock (m) or other value determined to be suitable through groundwater mounding analysis.


If R is greater than 20, consider decreasing catchment impervious area (Ai) by draining less area to the practice.

Size a bioretention cell where drainage area and practice area are fixed[edit]

If the land area is limited, determine the I/P ratio, which is the ratio of catchment impervious area (Ai) to practice pervious footprint area (Ap):

Where:

  • R = Ratio of catchment impervious area to practice pervious footprint area, also referred to as I/P ratio
  • Ap = Practice pervious footprint area in m2
  • Ai = Catchment impervious area in m2

Then calculate the required storage reservoir depth (dr), as:

Where:

  • D = Duration of design storm (h)
  • i = Intensity of design storm (m/h)
  • f' = Design infiltration rate (m/h)
  • n' = Effective porosity of the storage reservoir fill material

These equations assume that infiltration occurs primarily through the base of the facility.

This spreadsheet tool has been set up to perform all of the infiltration practice sizing calculations shown above.
Download the infiltration practice sizing tool

Calculate drawdown time[edit]

Two footprint areas of 9 m2.
Perimeter = 12 m (left) Perimeter = 20 m (right)

Download the Darcy drainage time calculator tool

In some situations, it may be possible to reduce the size of the bioretention required, by accounting for rapid drainage. Typically, this is only worth exploring over sandy soils with rapid infiltration. Note that narrow, linear bioretention features drain faster than round or blocky footprint geometries.

  • Begin the drainage time calculation by dividing the storage reservoir area of the practice (Ar) by the perimeter (x).
  • Use the following equation to estimate the time (t) to fully drain the facility:

Where:

  • n is the porosity of the storage reservoir fill material
  • Ar is the storage reservoir footprint area (m2),
  • f' is the design infiltration rate of the native soil (mm/h),
  • x is the perimeter of the practice (m), and
  • dr is the depth of the storage reservoir (m).

This 3 dimensional equation makes use of the hydraulic radius (Ar/x), where x is the perimeter (m) of the facility.
Maximizing the perimeter of the facility directs designers towards longer, linear shapes such as bioswales.