Line 328: Line 328:
*Confirm the surface ponding footprint area dimensions are within ±10% of the design and that the maximum surface ponding depth behind [[check dams]] meets design specifications;
*Confirm the surface ponding footprint area dimensions are within ±10% of the design and that the maximum surface ponding depth behind [[check dams]] meets design specifications;
*Check for side slope erosion/damage from vehicular/foot traffic.
*Check for side slope erosion/damage from vehicular/foot traffic.
|[[File:Perimeter bio pass.PNG|305px|thumb|center|The footprint area of the bioretention cell does not significantly deviate from the final design and should not negatively affect its stormwater management treatment performance.]]  
|[[File:Perimeter Pass swale.PNG|315px|thumb|center|The footprint area of the BMP does not significantly deviate from the final design and should not negatively affect its stormwater management treatment performance.]]  
|[[File:Perimeter bio fail.PNG|300px|thumb|center|The footprint area of the BMP is significantly smaller than what was specified in the final design of this example and differ greater than the recommended SWM criteria requirements (>10%).]]  
|[[File:Perimeter Fail swale.PNG|310px|thumb|center|The footprint area of the BMP is significantly smaller than what was specified in the final design of this example and differ greater than the recommended SWM criteria requirements (>10%), due to half the width having been paved over.]]  
|-
|-
|'''[[Enhanced swales: Specifications|Filter Bed]]'''
|'''[[Enhanced swales: Specifications|Filter Bed]]'''