Line 75: |
Line 75: |
|
| |
|
| '''Stormwater Management Strategy''' | | '''Stormwater Management Strategy''' |
| *Use a combination of increased topsoil depths, perforated storm sewers, stormwater management facility, and an infiltration facility to provide quality, quantity, and reduce runoff volumes to match pre-development.
| | #Use a combination of increased topsoil depths, perforated storm sewers, stormwater management facility, and an infiltration facility to provide quality, quantity, and reduce runoff volumes to match pre-development. |
| *Even with favorable soils and maximum use of infiltration techniques, site still requires quantity control storage for large storm events.
| | #Even with favorable soils and maximum use of infiltration techniques, site still requires quantity control storage for large storm events. |
|
| |
|
| <h3>Example 3: 3775-4005 Dundas St West (includes 2-6 Humber Hill Ave), Toronto</h3> | | <h3>Example 3: 3775-4005 Dundas St West (includes 2-6 Humber Hill Ave), Toronto</h3> |
Line 87: |
Line 87: |
|
| |
|
| '''Stormwater Strategy''' | | '''Stormwater Strategy''' |
| *Large portion of the roof proposed as green roof and cistern proposed in underground parking to capture remaining volume to meet 5 mm target. Water to be used for irrigation and carwash stations.
| | #Large portion of the roof proposed as green roof and cistern proposed in underground parking to capture remaining volume to meet 5 mm target. Water to be used for irrigation and carwash stations. |
| *Quality target achieved as majority of site is ‘clean’ roof water or directed to pervious area. Underground storage tank provided to satisfy municipal release rates to receiving storm sewer system.
| | #Quality target achieved as majority of site is ‘clean’ roof water or directed to pervious area. Underground storage tank provided to satisfy municipal release rates to receiving storm sewer system. |
| *Final design required both LIDs to reduce the overall runoff volumes, but also sub-surface storage chambers to provide quantity control to meet municipal requirements.
| | #Final design required both LIDs to reduce the overall runoff volumes, but also sub-surface storage chambers to provide quantity control to meet municipal requirements. |
| Due to underground parking limited opportunities for infiltration LIDs but used green roof to promote evapotranspiration, and cistern to reduce runoff volumes. | | Due to underground parking limited opportunities for infiltration LIDs but used green roof to promote evapotranspiration, and cistern to reduce runoff volumes. |
|
| |
|
| ==Data Analysis/Modelling== | | ==Data Analysis/Modelling== |