'''The fundamental components of an enhanced grassed swale are:'''
*Graded channel
*[[Turf: List| Resilient turf grass]]
*[[Check dams]], to facilitate short term ponding
'''Additional components may include:'''
*[[Absorbent landscapes| Amended soil]], to increase infiltration to soils below
*[[Liner|Impermeable membrane]], to prevent infiltration to soils below
*[[Turf reinforcement]], to prevent scour
 
==Planning considerations==
<h3>Best cross sections</h3>
[[File:Best X-section.png|thumb|Both sections a)triangular and, b)trapezoidal, are constrained within ratios of 8:1 H:V]]
[[File:Sections_perimeters.png|thumb|At lowest flow rates (smallest area) the trapezoidal swale (b) has the greater wetted perimeter; at higher flow rates (greater area) the triangular geometry (a)has a larger wetted perimeter for same area. Both channels modelled using ratios shown in figure above]]
Enhanced swales aim to both reduce the flow rate and retain a portion of the conveyed water. For these purposes the best x-section is that which maximizes the wetted perimeter for a given area.
 
 
 
===Check dams===
{{:Check dams}}
 
==Design==
All swales should be designed to meet the following criteria:
*Minimum residence time of 5 minutes.
*Maximum flow velocity 0.3 m/s
*Bottom width between 0.6 - 2.4 m
*Minimum length 30 m
 
{|class="wikitable"
|+ Slope variations
|-
|< 2 %||Use underdrain to distribute water for infiltration
|-
|2 - 5 %||Design swale for surface flow, consider check dams
|-
||5 %||Check dams required to reduce effective slope to 2 – 3 %
|}
 
Maximum depth of flow
{{plainlist|
*50% height of grass for regularly mown swales, to maximum of 75 mm.
*33% height of vegetation for infrequently mown swales.
|}}
 
<h3>Modeling</h3>
{{:Swales: TTT}}
 
<h3>Materials</h3>
{{:Turf: List}}