Pretreatment features
(view source)
Revision as of 15:16, 12 June 2018
1 byte added
,
6 years ago
m
→Example calculation
Line 35:
Line 35:
:<math>V_{f}=1.7\times 0.8\times 0.6\times 1=0.816\ m^{3}</math>
:<math>V_{f}=1.7\times 0.8\times 0.6\times 1=0.816\ m^{3}</math>
The area required to keep the maximum head of water within the forebay to 0.15 m is calculated as:
The area required to keep the maximum head of water within the forebay to 0.15 m is calculated as:
:<math>A_{f}=\frac{0.816}{0.
1
}=
8
.
16
\ m^{2}</math>
:<math>A_{f}=\frac{0.816}{0.
15
}=
5
.
44
\ m^{2}</math>
The area required to settle the 1 mm particles is calculated as:
The area required to settle the 1 mm particles is calculated as:
:<math>A_{f}=120\times 0.1 = 12\ m^{2}</math>
:<math>A_{f}=120\times 0.1 = 12\ m^{2}</math>