Total life cycle cost estimates for the two [[Infiltration trenches|infiltration trench]] configurations vary substantially with the [[Infiltration trenches|Infiltration Trench: Partial Infiltration]] design being highest ($85,288.88), followed closely by the [[Infiltration trenches|Infiltration Trench: Full Infiltration]] design being ($69,805.90).<br>
Total life cycle cost estimates for the [[Enhanced swale]] Full Infiltration design configuration is ($23,451.36), makign it one of the cheapest LID BMP options.<br>


It is notable that a sensitivity analysis was conducted in 2019 to compare construction cost estimates generated by the tool to actual costs of implemented projects. '''The analysis found that tool estimates were typically within ±14% of actual construction costs'''<ref>Credit Vally Conservation (CVC). 2019. Life-cycle costing tool 2019 update: sensitivity analysis. Credit Valley Conservation, Mississauga, Ontario. https://sustainabletechnologies.ca/app/uploads/2020/04/LCCT-Sensitivity-Analysis_March2020.pdf</ref>
It is notable that a sensitivity analysis was conducted in 2019 to compare construction cost estimates generated by the tool to actual costs of implemented projects. '''The analysis found that tool estimates were typically within ±14% of actual construction costs'''<ref>Credit Vally Conservation (CVC). 2019. Life-cycle costing tool 2019 update: sensitivity analysis. Credit Valley Conservation, Mississauga, Ontario. https://sustainabletechnologies.ca/app/uploads/2020/04/LCCT-Sensitivity-Analysis_March2020.pdf</ref>


===Full Infiltration===
===Full Infiltration===
[[File:North Dakota State U infiltration trench.jpg|800px|thumb|Good use of geotextile, being limited to preventing fines from entering the trench from above. Read more about the performance of this feature in comparison to [[bioretention]]] BMPs in Vaughan, ON. (Source: STEP, 2016<ref>Performance Comparison of Surface and Underground Stormwater Infiltration Practices - TECHNICAL BRIEF. Low Impact Development Series. https://sustainabletechnologies.ca/app/uploads/2016/08/BioVSTrench_TechBrief__July2015.pdf</ref>)]]
[[File:CVC Office, Grass Swale.JPG|500px|thumb|Enhanced Grass [[swale]] in CVC headquarters parking lot, Mississauga ON.]]


[[File:Design Table InfilTrench Full Infil.PNG|700px]]<br>
[[File:Design Table EnhancedSwales Full Infil.PNG|700px]]<br>
</br>
===Partial Infiltration===
[[File:Design Table InfilTrench Partial Infil.PNG|700px]]<br>
</br>
</br>