Line 12: |
Line 12: |
| !Applicable in pollution hotspots <ref>Suitable in pollution hot spots or runoff source areas where land uses or activities have the potential to generate highly contaminated runoff</ref> | | !Applicable in pollution hotspots <ref>Suitable in pollution hot spots or runoff source areas where land uses or activities have the potential to generate highly contaminated runoff</ref> |
| !Set backs | | !Set backs |
| !Water table separation<ref>Must have adequate separation from the seasonally high water table or top of bedrock elevation</ref> | | !Karst<ref>Suitability in areas of karst geologic formations</ref> |
| !Wellhead protection area<ref>|Time-of-travel within wellhead protection areas</ref> | | !Wellhead protection area<ref>|Time-of-travel within wellhead protection areas</ref> |
| |- | | |- |
| |'''[[Rain barrels|Rain Barrel]]''' | | |'''[[Rain barrels|Rain Barrel]]''' |
| |Not applicable | | |Not applicable |
| ||5 to 50 m<sup>2</sup>||Not applicable||1||0||NA||Yes||None||No||None | | ||5 to 50 m<sup>2</sup>||Not applicable||1||0||NA||Yes||None||Yes||None |
| |- | | |- |
| |'''[[rainwater harvesting|Cistern]]''' | | |'''[[rainwater harvesting|Cistern]]''' |
| |Not applicable | | |Not applicable |
| |1:1||Not applicable||0||0||0||Yes||None||No||None | | |1:1||Not applicable||0||0||0||Yes||None||Yes||None |
| |- | | |- |
| |'''[[Downspout disconnection|Roof downspout disconnection]]''' | | |'''[[Downspout disconnection|Roof downspout disconnection]]''' |
| |Not applicable | | |Not applicable |
| |5 to 100 m<sup>2</sup>||Amend if < 15 mm/hr||0.5||5 to 20||1 to 5||Yes||Building Foundation||No||None | | |5 to 100 m<sup>2</sup>||Amend if < 15 mm/hr||0.5||5 to 20||1 to 5||Yes||Building Foundation||Yes||None |
| |- | | |- |
| |'''Soakaway, infiltration trench or chamber''' | | |'''Soakaway, infiltration trench or chamber''' |
| |1 | | |1 |
| |5:1 to 20:1||Not a constraint||1 to 2||0 to 1||<15 %||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||Yes||2 yr | | |5:1 to 20:1||Not a constraint||1 to 2||0 to 1||<15 %||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||No||2 yr |
| |- | | |- |
| |'''[[Bioretention]]''' | | |'''[[Bioretention]]''' |
| |1 | | |1 |
| |5:1 to 15:1||[[Underdrain]] recommended<br>if < 15 mm/hr||1 to 2||5 to 10||0 to 2||No (infiltrating); Yes (non-infiltrating)||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||Yes||2 yr (infiltrating); None (non-infiltrating) | | |5:1 to 15:1||[[Underdrain]] recommended<br>if < 15 mm/hr||1 to 2||5 to 10||0 to 2||No (infiltrating); Yes (non-infiltrating)||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||No (infiltrating); Yes (non-infiltrating)||2 yr (infiltrating); None (non-infiltrating) |
| |- | | |- |
| |'''[[Stormwater planters]]''' | | |'''[[Stormwater planters]]''' |
| |Not applicable | | |Not applicable |
| |5:1||Not a constraint||1 to 2||2 to 5||0 to 2||No (infiltrating); Yes (non-infiltrating)||Building Foundation, Trees||No||2 Yr (infiltrating); None (non-infiltrating) | | |5:1||Not a constraint||1 to 2||2 to 5||0 to 2||No (infiltrating); Yes (non-infiltrating)||Building Foundation, Trees||No (infiltrating); Yes (non-infiltrating)||2 Yr (infiltrating); None (non-infiltrating) |
| |- | | |- |
| |'''[[Vegetated filter strip]]''' | | |'''[[Vegetated filter strip]]''' |
| |1 | | |Not applicable |
| |5:1||Amend if < 15 mm/hr||0 to 1||15 to 20||1 to 5||No||None||No||None | | |5:1||Amend if < 15 mm/hr||0 to 1||15 to 20||1 to 5||No||None||Yes||None |
| |- | | |- |
| |'''[[Permeable pavement]]''' | | |'''[[Permeable pavement]]''' |
| |1 | | |1 |
| |1:1 to 1.2:1||Underdrain recommended <br> if < 15 mm/hr||0.5 to 1||0||1 to 5||No (infiltrating); Yes (non-infiltrating)||4m-Underground Utilities<br>Drinking Water Wellhead<br>Protection Areas||Yes||2 Yr (infiltrating); None (non-infiltrating) | | |1:1 to 1.2:1||Underdrain recommended <br> if < 15 mm/hr||0.5 to 1||0||1 to 5||No (infiltrating); Yes (non-infiltrating)||4m-Underground Utilities<br>Drinking Water Wellhead<br>Protection Areas||No (infiltrating); Yes (non-infiltrating)||2 Yr (infiltrating); None (non-infiltrating) |
| |- | | |- |
| |'''[[Enhanced grass swale]](has checkdams)''' | | |'''[[Enhanced grass swale]](has checkdams)''' |
| |1 | | |Not applicable |
| |5:1 to 10:1||Not applicable||1 to 3||5 to 15||0.5 to 6||No||4m- Building Foundation<br>Underground Utilities||Yes||None | | |5:1 to 10:1||Not applicable||1 to 3||5 to 15||0.5 to 6||No||4m- Building Foundation<br>Underground Utilities||Yes||None |
| |- | | |- |
| |'''[[Dry swale]] (Bioswale)''' | | |'''[[Dry swale]] (Bioswale)''' |
| |1 | | |1 |
| |5:1 to 15:1||Underdrain recommended <br> if < 15 mm/hr||1 to 3||5 to 10||0.5 to 6||No (infiltrating); Yes (non-infiltrating)||4m (3m if impermeable liner<br>is used) Building foundation,<br> Underground utilities,<br> Drinking Water Wellhead Protection Areas||Yes||2 Yr (infiltrating); None (non-infiltrating) | | |5:1 to 15:1||Underdrain recommended <br> if < 15 mm/hr||1 to 3||5 to 10||0.5 to 6||No (infiltrating); Yes (non-infiltrating)||4m (3m if impermeable liner<br>is used) Building foundation,<br> Underground utilities,<br> Drinking Water Wellhead Protection Areas||No (infiltrating); Yes (non-infiltrating)||2 Yr (infiltrating); None (non-infiltrating) |
| |- | | |- |
| |'''[[Perforated pipe system]]''' | | |'''[[Perforated pipe system]]''' |
| |1 | | |1 |
| |5:1 to 10:1||Not a constraint||1 to 3||0||< 15%||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||Yes||2 Yr | | |5:1 to 10:1||Not a constraint||1 to 3||0||< 15%||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||No||2 Yr |
| |} | | |} |