* Step 4: Calculate the surface (i.e footprint) area of the practice (A<sub>p</sub>) needed to capture runoff produced from the catchment during the design storm event:<br>
* Step 4: Calculate the surface (i.e footprint) area of the practice (A<sub>p</sub>) needed to capture runoff produced from the catchment during the design storm event:<br>
For practices where flow is delivered to the filter media bed:
For practices where flow is delivered to the filter media bed:
<math>A_{p}=i\times D\times A_{i}/[(d_{p} + (f_{m, min} \times D)]</math>
<math>A_{p}=i\times D\times A_{i}/[(d_{p}' + (f_{m, min} \times D)]</math>
{{Plainlist|1=Where:
{{Plainlist|1=Where:
*i = Design storm intensity (mm/h)
*i = Design storm intensity (mm/h)