| This method of determining [[design infiltration rate]] is only approved for sandy native soils with d<sub>10</sub> between 0.1 - 2.5 mm (i.e. soils to which the Hazen formula is applicable)<ref>San Francisco Public Utilities Commission. (2017). Determination of Design Infiltration Rates for the Sizing of Infiltration‐based Green Infrastructure Facilities. Retrieved from http://sfwater.org/modules/showdocument.aspx?documentid=9681</ref>. | | This method of determining [[design infiltration rate]] is only suitable for coarse-textured native soils with d<sub>10</sub> between 0.1 - 2.5 mm (i.e. soils to which the Hazen formula is applicable)<ref>San Francisco Public Utilities Commission. (2017). Determination of Design Infiltration Rates for the Sizing of Infiltration‐based Green Infrastructure Facilities. Retrieved from http://sfwater.org/modules/showdocument.aspx?documentid=9681</ref>. |
|
| |
|
| '''This method must not be applied within areas of fill or in regions where hydraulic conductivity is controlled by vertical fractures in the soil matrix.''' | | '''This method must not be applied within areas of fill or in regions where hydraulic conductivity is controlled by vertical fractures in the soil matrix.''' |
Line 7: |
Line 7: |
| #* For [[bioretention]] facilities, analyze each defined layer below the proposed facility bottom to a depth of at least 3 times the maximum ponding depth, but not less than 1 m. | | #* For [[bioretention]] facilities, analyze each defined layer below the proposed facility bottom to a depth of at least 3 times the maximum ponding depth, but not less than 1 m. |
| #* For [[permeable paving]], analyze each defined layer below the proposed facility bottom to a depth of at least 3 times the maximum depth of water within the base course, but not less than 1 m. | | #* For [[permeable paving]], analyze each defined layer below the proposed facility bottom to a depth of at least 3 times the maximum depth of water within the base course, but not less than 1 m. |
| #* For other types of infiltration facilities serving drainage areas up to 4 Ha, analyze each defined layer below the proposed facility bottom to a depth of at least 2.5 times the maximum depth of water in the facility, but not less than 3 m. | | #* For other types of infiltration facilities serving drainage areas up to 4 Ha, analyze each defined layer below the proposed facility bottom to a depth of at least 2.5 times the water storage reservoir depth, but not less than 3 m. |
| # Submit the soil samples to a certified soil testing laboratory for grain-size, or particle-size distribution analysis according to [https://www.astm.org/Standards/D422.htm ASTM D422] Standard Test Method for Particle-size Analysis of Soils. | | # Submit the soil samples to a certified soil testing laboratory for grain-size, or particle-size distribution analysis according to [https://www.astm.org/Standards/D422.htm ASTM D422] Standard Test Method for Particle-size Analysis of Soils. |
|
| |
|
| ===Data Analysis=== | | ===Data Analysis=== |
| NB: The Hazen formula method of estimating soil permeability based on grain size distribution analysis is only suitable for soils with d<sub>10</sub> between 0.1 and 2.5 millimeters <ref>Hazen, A. (1893). Some physical properties of sand and gravel with special reference to the use in filtration. 4th Annual Report, State Board of Health, Boston.</ref>. The soil permeability value estimated using the Hazen method can be considered to be the measured infiltration rate of the soil, f, in mm/h | | NB: The Hazen formula method of estimating soil permeability based on grain size distribution analysis is only suitable for coarse-textured soils with d<sub>10</sub> between 0.1 and 2.5 millimeters <ref>Hazen, A. (1893). Some physical properties of sand and gravel with special reference to the use in filtration. 4th Annual Report, State Board of Health, Boston.</ref>. The soil permeability value estimated using the Hazen method can be considered to be the measured infiltration rate of the soil, f, in mm/h |
| :<math>f=C\cdot {\left (d_{10}\right )^{2}}</math> | | :<math>f=C\cdot {\left (d_{10}\right )^{2}}</math> |
|
| |
|
Line 19: |
Line 19: |
|
| |
|
| {| class="wikitable" | | {| class="wikitable" |
| ! colspan =2| Shape factors (C) to yield K in mm/h | | ! colspan =2| Shape factors (C) to yield f in mm/h |
| |- | | |- |
| |Very fine to fine sand | | |Very fine to fine sand |