Line 8: |
Line 8: |
| |'''Pervious concrete''' | | |'''Pervious concrete''' |
| | | | | |
| * 28 day compressive strength = 5.5 to 20 MPa | | * NO4-RG-S7 mix with air entrainment proven to have the best freeze-thaw durability after 300 freeze-thaw cycles. |
| * Void ratio = 14% - 31% | | * 28 day compressive strength = 5.5 to 20 MPa. |
| * Permeability = 900 - 21,500 mm/hr | | * Porosity between 14% to 31%. |
| |Thickness will range from 100 mm - 150 mm depending on the expected loads | | * Permeability = 900 to 21,500 mm/hr. |
| | * Proprietary pre-cast slabs meeting required specifications are also available. |
| | |Thickness will range from 100 mm - 150 mm depending on the expected loads. |
| |- | | |- |
| |'''Porous asphalt''' | | |'''Porous asphalt''' |
| | | | | |
| * open-graded asphalt mix with a minimum of 16 % air voids | | * Open-graded asphalt mix with a minimum porosity of 16%. |
| * Polymer can be added to provide additional strength to heavy loads | | * Polymers can be added to provide additional strength to heavy loads. |
| |Thickness will range from 50 mm - 100 mm depending on the expected loads | | *The University of New Hampshire Stormwater Center has detailed design specifications for porous asphalt. |
| | |Thickness will range from 50 mm - 100 mm depending on the expected loads. |
| |- | | |- |
| |'''Permeable pavers''' | | |'''Permeable Interlocking Pacements''' |
| | | | | |
| *ASTM No. 8(5 mm dia) crushed aggregate is recommended for fill material in the paver openings. | | *Pavers shall meet the minimum material and standard specifications for precast concrete pavers (CSA A231.2 in Canada; ASTM C936 in United States). |
| *Pavers shall meet the minimum material and standard specification for precast concrete pavers. | | *Open space between pavers (i.e. joint space) typically ranges between 5 and 15% of the total surface area. |
| *Pigment in concrete pavers shall conform to ASTM C 979 ACI Report No. 212.3R provides guidance on the use of pigments.
| | *ASTM No. 8 (5 mm dia.) crushed aggregate is recommended for fill material in the paver joints (typically HPB). |
| *Maximum allowable breakage of product is 5%
| | *For narrow joint pavers, a smaller sized aggregate may be used. Narrow joints are required where pavement must be AODA compliant. |
| | | | | |
| *For vehicle applications the minimum paver thickness is 80 mm | | *For vehicle applications the minimum paver thickness is 80 mm |
| *For pedestrian applications is 60 mm and joint widths should be no greater than 15 mm. | | *For pedestrian applications the minimum paver thickness is 60 mm and joint widths should be no greater than 15 mm. |
| |} | | |} |