To calculate the time (''t'') to fully drain the facility assuming three-dimensional drainage:  
To calculate the time (''t'') to fully drain the facility assuming three-dimensional drainage:  
<math>t=\frac{n\times A_{r}}{f'\times x}ln\left [ \frac{\left d_{r} + (\frac{A_{r}}{x} \right)}{\left(\frac{A_{r}}{x}\right)}\right]</math>
<math>t=\frac{n\times A_{r}}{f'\times x}ln\left [ \frac{\left (d_{r} + \frac{A_{r}}{x} \right)}{\left (\frac{A_{r}}{x}\right) }\right]</math>
Where "ln" means natural logarithm of the term in square brackets <br>
Where "ln" means natural logarithm of the term in square brackets <br>
Adapted from CIRIA, The SUDS Manual C753 (2015).