Line 15: Line 15:
!Wellhead protection area<ref>| Drinking Water Source Protection wellhead protection area time of travel</ref>
!Wellhead protection area<ref>| Drinking Water Source Protection wellhead protection area time of travel</ref>
|-
|-
|'''[[Rain barrels|Rain Barrel]]'''
|'''[[Rain barrels|Rain Barrels]]'''
|Not applicable
|Not applicable
||5 to 50 m<sup>2</sup>||Not applicable||1||0||NA||Yes||None||Yes||None
||5 to 50 m<sup>2</sup>||Not applicable||1||0||NA||Yes||None||Yes||None
|-
|-
|'''[[rainwater harvesting|Cistern]]'''
|'''[[rainwater harvesting|Cisterns]]'''
|Not applicable
|Not applicable
|1:1||Not applicable||0||0||0||Yes||None||Yes||None
|1:1||Not applicable||0||0||0||Yes||None||Yes||None
Line 51: Line 51:
|5:1 to 10:1||Not applicable||1 to 3||5 to 15||0.5 to 6||No||4m- Building Foundation<br>Underground Utilities||No||2 Yr
|5:1 to 10:1||Not applicable||1 to 3||5 to 15||0.5 to 6||No||4m- Building Foundation<br>Underground Utilities||No||2 Yr
|-
|-
|'''[[Bioswale]] (Dry swale)'''
|'''[[Bioswales]] (Dry swale)'''
|1 (infiltrating); Not applicable (non-infiltrating)
|1 (infiltrating); Not applicable (non-infiltrating)
|5:1 to 15:1||Underdrain recommended <br> if < 15 mm/hr||1 to 3||5 to 10||0.5 to 6||No (infiltrating); Yes (non-infiltrating)||4m (3m if impermeable liner<br>is used) Building foundation,<br> Underground utilities,<br> Drinking Water Wellhead Protection Areas||No (infiltrating); Yes (non-infiltrating)||2 Yr (infiltrating); None (non-infiltrating)
|5:1 to 15:1||Underdrain recommended <br> if < 15 mm/hr||1 to 3||5 to 10||0.5 to 6||No (infiltrating); Yes (non-infiltrating)||4m (3m if impermeable liner<br>is used) Building foundation,<br> Underground utilities,<br> Drinking Water Wellhead Protection Areas||No (infiltrating); Yes (non-infiltrating)||2 Yr (infiltrating); None (non-infiltrating)
Line 59: Line 59:
|5:1 to 10:1||Not a constraint||1 to 3||0||< 15%||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||No||2 Yr
|5:1 to 10:1||Not a constraint||1 to 3||0||< 15%||No||4m- Building Foundation<br>Underground Utilities, Trees,<br>Drinking Water Wellhead<br>Protection Areas||No||2 Yr
|-
|-
|'''[[Stormwater Tree Trenches]]'''
|'''[[Stormwater Tree Trenches|Stormwater tree trenches]]'''
|1  
|1  
|5:1 to 15:1||[[Underdrain]] recommended<br>if < 15 mm/hr||1 to 2||5 to 10||0 to 2||No||4m- Building Foundation<br>Underground Utilities, <br>Drinking Water Wellhead<br>Protection Areas||No||2 yr
|5:1 to 15:1||[[Underdrain]] recommended<br>if < 15 mm/hr||1 to 2||5 to 10||0 to 2||No||4m- Building Foundation<br>Underground Utilities, <br>Drinking Water Wellhead<br>Protection Areas||No||2 yr